Symptomor error FRUor action, in sequence
0231
SystemRAM errorSystem
RAMfails at offset nnnn.
1. DIMM.
2. Systemboard.
0232
ExtendedRAM
errorExtendedRAM fails at
offsetnnnn.
1. DIMM.
2. Systemboard.
0250
Systembattery errorSystem
batteryis dead.
Replacethe backup battery
andrun IBM BIOS Setup
Utilityto reset the time and
date.
0251
SystemCMOS checksum
badDefaultconfiguration
used.
Replacethe backup battery
andrun IBM BIOS Setup
Utilityto reset the time and
date.
0252
Passwordchecksum badThe
passwordis cleared.
Resetthe password by
runningIBM BIOS Setup
Utility.
0260
Systemtimer error 1. Replace the backup
batteryand run IBM BIOS
SetupUtility to reset the
timeand date.
2. Systemboard.
0270
Realtime clock error 1. Replacethe backup
batteryand run IBM BIOS
SetupUtility to reset the
timeand date.
2. Systemboard.
0271
Dateand time errorNeither
thedate nor the time is set in
thecomputer.
RunIBM BIOS Setup Utility to
resetthe time and date.
0280
Previousboot
incompleteDefault
configurationused.
1. LoadSetup Defaultin
IBMBIOS Setup Utility.
2. DIMM.
3. Systemboard.
02B2
Incorrectdrive A type 1. Diskettedrive.
2. ExternalFDD cable.
3. I/Ocard.
02F4
EISACMOS not writable 1. LoadSetup Defaults in
IBMBIOS Setup Utility.
2. Replacethe backup battery.
3. Systemboard.
02F5
DMAtest failed 1. DIMM.
2. Systemboard.
02F6
SoftwareNMI failed 1. DIMM.
2. Systemboard.
02F7
Fail-safetimer NMI failed 1. DIMM.
2. Systemboard.
Symptom-to-FRUindex
52 ThinkPad T30 (MT 2366, 2367)