Symptom / Error FRU / Action in Sequence
111
(I/O parity.) 1. Go to “Memory
Checkout” on
page 128.
2. Systemboard
161
(Dead battery.) 1. Go to “Checking the
Backup Battery” on
page 134.
2. Backupbattery
3. Systemboard
163
(Time and date was not
set.)
1. Set time and date
2. Systemboard
173
(Configuration data was
lost.)
1. Select OK in the error
screen; then set the
time and date.
2. Backupbattery
3. Systemboard
174
(Configuration error:
Perform“Checking the
Installed Devices List” on
page 152 before changing
any FRUs.)
1.Check device
configuration.
2. Hard disk drive
assembly
3. Systemboard
184
(POP check sum error.) 1. Reset the POP
(power-on password)
in Easy-Setup.
190
(Depleted battery pack was
installed when the power
was on.)
1. Go to “Checking the
Battery Pack” on
page 133.
191XX
(PM initialization error.) 1. System board
195
(The configuration read from
the hibernation area does
not match the actual
configuration.)
1. Check if the
configuration was
changed.
For example, check if
the DIMM card is
added.
196
(Read error occurred in the
hibernation area of the
HDD.)
1. Run the hard disk
drive test.
2. Hard disk drive
1XX 1.System board
ThinkPad 560, 560E (2640) 139