Symptom / Error FRU / Action in Sequence
185
(The startup sequence is
not valid. Suspect that
power was off when the
startup sequence was being
updated.)
1. Reset the startup
sequence in
Easy-Setup.
186 1.System board
188
(EEPROM CRC #2 error.) 1. Set the system
identification using
the ThinkPad
Hardware
Maintenance
Diskette.
190
(Depleted battery pack was
installed when the power
was on.)
1. Go to “Checking the
Battery Pack” on
page 215.
191XX
(PM initialization error.) 1.System board
2. CPUcard
195
(The configuration read from
the hibernation area does
not match the actual
configuration.)
1. Check if the
configuration was
changed.
For example, check if
the disk drive is from
another computer.
196
(Read error occurred in the
hibernation area of the
HDD.)
1. Run the hard disk
drive test.
2. Hard disk drive
1XX 1.System board
2XX
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
1. Go to “Memory
Checkout” on
page 206.
2. DIMM, or DIMM
Adapter
3. Systemboard
301, 303, 304, 305, 3XX
(301: Keyboard error.) 1. Go to “Keyboard and
Auxiliary Input
Device Checkout” on
page 209.
2. Keyboard
3. Videocard
4. Externalnumeric
keypad
5. Externalkeyboard
6. Keyboard/mousecable
7. Systemboard
ThinkPad 760 (9546, 9547) 225