UltraBay II Tray-Related Symptoms
Symptom or Error FRUs of the SelectaDock
Sequence of Actions
The HDD or FDD on the
UltraBay II tray does not
work correctly.
1. Reseat the drive.
2. Reseat the power
cable and SCSI cable
of the of the UltraBay II
tray. (See “UltraBay II
Tray” on page 660.)
3. Check that:
a. The drive works
correctly if it is
installed in the
UltraBay or
UltraBay II of the
computer.
b. The IDE
connector of the
UltraBay II tray is
connected
correctly.
c. No more than two
IDE devices are
installed including
a device in the
device space bay.
4. Run the drive test.
5. Main card.
USB Related Symptoms
Symptom or Error FRUs of the SelectaDock
Sequence of Actions
USB device does not work. Verify that:
The device self-test runs
correctly.
Check that:
1. Connect the device to
the computer and
works.
2. Make sure that the
device is set correctly.
3. Run the advanced
diagnostic test for the
USB.
4. Main card.
5. USB card.
6. USB cable.
650 IBM Mobile Systems HMM