Symptom / Error FRU / Action in Sequence
861X
(Pointing device error when
TrackPoint III is disabled.)
8611: Systembus
error—I/F between
8042 and IPDC.
8612: TrackPointerror.
8613: System board or
TrackPoint error.
1. Reseat the keyboard
connector on the
video card.
2. Reseat the TrackPoint
III cable on the
keyboard card.
3. Keyboard
4. Externalmouse
5. Videocard
6. Systemboard
I9990301
I9990302
I9990305
I9990301: Harddisk
error.
I9990302: Invalidhard
disk boot record.
I9990305: Nobootable
device.
1. Check that the
operating system is
installed in the HDD.
If not, install the
operating system.
2. Reseat the boot
device.
3. Check the startup
sequence for the
correct boot device.
4. Check that the
operating system has
no failure and is
installed correctly.
I9990303
(Bank–2 flash ROM check
sum error.)
System board
Other codes, not in this
list Go to “Undetermined
Problems” on page 447.
Diagnostic Error Codes
If an error is detected, the following appears:
Large X on the left side of the device icon.
Device ID (three digits)
Error code (two digits)
FRU code (four digits)
The device ID and error code indicate the detailed portion
of the FRU that caused the error. If replacing a FRU does
not correct the problem, see the device ID or error code
from the previous failure. If they have changed, the cause
might be because the new FRU is detective or that the
FRU was incorrectly installed.
Device ID: If an error is detected by the diagnostic
tests, a three-digit device ID is displayed, indicating the
suspected device.
436 IBM Mobile Systems HMM