Table17. MCT command definitions (continued)
DEC HEX MCT Default Min Max
204 CC Scan1storage template #2 predefined
location X3
205 CD Scan1storage template #2 predefined
location Y3
206 CE Scan1storage template #2 predefined
location DX3
207 CF Scan1storage template #2 predefined
location DY3
Notes:
1. See “Store scanned image and/or select partial image for retrieval” on page 169
Setup commands

Setup commands change character font, intercharacter spacing, and the target print

station.

Set print mode

EIA-232 Syntax:

ESC ! nor X'1B;21;n'

where:

nSpecifies print characteristics, such as user-defined thermal and

impact code pages.

Bit Number Function Bit=0 Bit=1 Thermal Impact
(LSB) 0 Char/Page0 See Below See Below yes yes
1 Char/Page1 See Below See Below yes yes
2 Overline Cancel Set yes no
3 Emphasized Cancel Set yes yes
4 Double-high Cancel Set yes yes
5 Double-wide Cancel Set yes yes
6 Inverted Mode Cancel Set yes no
(MSB) 7 Underlined Cancel Set yes no
Table18. Fonts for Models TI3, TI4, TG3, TG4, TG8, TG9, TI8, TI9, TF6, and TM6
Bit 0 Bit 1 User-Defined Thermal
Code Page
User-Defined Impact Code
Page @ Density
Resident
Thermal
Resident
Impact
0 0 CodePage 1 Code Page 1 @ 150 half-dots
per inch
FontA FontA
1 0 CodePage 2 Code Page 1 @ 120 half-dots
per inch
Font B Font B
0 1 CodePage 3 Code Page 2 @ 150 half-dots
per inch
Font C FontA
1 1 CodePage 4 Code Page 2 @ 120 half-dots
per inch
Reserved Font B
1.
Updated April 2, 2009
AppendixD. EIA-232 programming information 129