Table24. Retrievable usage data (continued)
Hex Value Usage Data Being Tracked Factor
86 Number of failed paper cuts - single-station printers only None
87 Number of characters printed at the DI (impact) station -
thermal/impact printers only (see Note 1)
1000
88 Number of steps performed by the DI paper feed motor 50000
89 Number of DI transport motor starts 5000
8A Numberof home errors - thermal/impact printers only (see
Note 2)
None
8B Numberof times the DI cover was opened - thermal/impact
printers only (see Note 2)
None
8C Numberof forms that were inserted into the DI station -
thermal/impact printers only
100
8D Numberof MICR reads - Tx4, Tx8, Tx9 16
8E Numberof high-interference MICR reads 8
8F Numberof failed MICR reads 8
90 Number of check flips performed 16
91 Number of check flip failures 8
92 Remainder value of CR motor steps (from 0x84) (see Note
2)
None
93 Remainder values of paper cuts (from #0x84) (see Note 1
and 2)
None
94 Remainder values of DI characters printed (from #0x87) (see
Note 1 and 2)
None
95 Remainder values of DI paper feed motor steps (from #0x88)
(see Note 2)
None
96 Remainder values of forms inserted into DI station (from
#0x8C) (see Note 2)
None
97 Remainder values of DI transport motor starts (from #0x89)
(see Note 2)
None
98 Remainder values of check flip failures - Tx4, Tx8, Tx9 (from
#0x91) (see Note 2)
None
99 Remainder values of failed MICR reads - Tx4, Tx8, Tx9
(from #0x8F) (see Note 2)
None
9A Remaindervalues of check flips performed - Tx4, Tx8, Tx9
(from #0x90) (see Note 2)
None
9B Remaindervalues of MICR reads - Tx4, Tx8, Tx9 (from
#0x8D) (see Note 2)
None
9C Remaindervalues of high interference MICR reads - Tx4,
Tx8, Tx9 (from #0x8E) (see Note 2)
None
9D Remaindervalues of bar codes printed (from #0xD8) (see
Note 2)
None
9E Remaindervalues of scanned documents - Tx8, Tx9 only
(from #0xD3) (see Note 2)
None
9F Remaindervalues of cash drawer successful (from #0xD6)
(see Note 2)
None
D2 Numberof flash erase commands performed (NVRAM write
count) (see Note 2)
None
Updated April 2, 2009