5-3 SOFTWARE ADJUSTMENT

5-3 SOFTWARE ADJUSTMENT

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

MEASUREMENT

 

 

VALUE

 

 

 

 

 

 

 

UNIT

 

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFERENCE

 

1

• Operating frequency:

Top

Loosely

couple a

frequnecy

136.00000 MHz

FREQUENCY

 

 

136.000 MHz (L-band)

panel

counter to the antenna connec-

 

(L-band)

[TXF]

 

 

146.000 MHz (H-band)

 

tor.

 

 

146.00000 MHz

 

 

 

• High/Low switch

: Low

 

 

 

 

 

(H-band)

 

 

 

• Connect the RF power meter or 50 Ω

 

 

 

 

 

 

 

 

 

 

dummy load to the antenna connector.

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Transmitting

 

 

 

 

 

136.001360 MHz

 

 

 

 

 

 

 

 

 

 

(L-band)

 

 

 

 

 

 

 

 

 

146.001460 MHz

 

 

 

 

 

 

 

 

 

 

(H-band)

 

 

 

 

 

 

 

 

 

OUTPUT

 

1

• Operating frequency:

Top

Connect an RF power meter to

 

1.0 W

POWER

 

 

136.000 MHz (L-band)

panel

the antenna connector.

 

 

 

[POWER (LO)]

 

 

146.000 MHz (H-band)

 

 

 

 

 

 

 

 

 

 

• High/Low switch

: Low

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[POWER (HI)]

 

2

• High/Low switch

: High

 

 

 

 

 

5.0 W

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM

 

1

• Operating frequency:

Top

Connect an FM deviation meter

±4.1 kHz (W-type)*1

DEVIATION

 

 

136.000 MHz (L-band)

panel

to the

antenna

connector

±3.3 kHz (M-type)

[MOD]

 

 

146.000 MHz (H-band)

 

through the attenuator.

±2.0 kHz (N-type)*1

 

 

 

• High/Low switch

: Low

 

 

 

 

 

 

 

 

 

 

• Connect the audio generator to the

 

 

 

 

 

 

 

 

 

 

[MIC] jack and set as

 

 

 

 

 

 

 

 

 

 

 

: 1.0 kHz/150 mVrms

 

 

 

 

 

 

 

 

 

 

• Set the FM deviation meter as:

 

 

 

 

 

 

 

 

 

 

HPF

: OFF

 

 

 

 

 

 

 

 

 

 

LPF

: 20 kHz

 

 

 

 

 

 

 

 

 

 

De-emphasis

: OFF

 

 

 

 

 

 

 

 

 

 

Detector

: (P–P)/2

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DTCS WAVE

 

1

• Operating frequency:

Top

Connect an FM deviation meter

Set to flat wave

FORM

 

 

143.000 MHz (L-band)

panel

with an oscilloscope to the

form

[DTCS BAL]

 

 

160.000 MHz (H-band)

 

antenna

connector

through an

 

 

 

 

 

 

• High/Low switch

: Low

 

attenuator.

 

 

 

 

 

 

 

• No audio applied to the [MIC] jack.

 

 

 

 

 

 

 

 

 

 

• DTCS code

: 007

 

 

 

 

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1W/N-type must adjust both (W-type) and (N-type).