Icom IC-F3GS, IC-F3GT service manual Top view, Dc Power Cable Connections, computer

Models: IC-F3GS

1 83
Download 83 pages 55.86 Kb
Page 54
Image 54
computer

 DC POWER CABLE CONNECTIONS CONNECTION

Standard signal generator to the antenna connector

to [MIC]

0.1 V to 32 mV

Audio generator

( 127 dBm to

 

17 dBm)

 

 

 

CAUTION:

DO NOT transmit while an SSG is connected to the antenna connector.

to an RS-232C port

 

 

Personal

OPC-478

computer

FM

deviation meter

Attenuator

40 dB or 50 dB

RF power meter 0.1 10 W/50 Manual background

Frequency

counter

DB9 female plug

(incl. level converter circuit)

to [SP]

SINAD meter

JIG cable

Speaker (8 Manual background)

Manual background DC POWER CABLE CONNECTIONS

SOFTWARE ADJUSTMENT

+

DC POWER

SUPPLY

GND

Battery type detector

DC POWER

SUPPLY

Soldering

DC cable here

PLL ADJUSTMENT

+

NOTE: When you adjust the output power (high power), the battery type detector must be con- nected to GND (see illustration at above). Ohterwise the transceiver does not transmit high power, the output power will be low.

Top view

5 - 3

Page 54
Image 54
Icom IC-F3GS, IC-F3GT service manual Top view, Dc Power Cable Connections, computer