SOFTWARE ADJUSTMENT – continued

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

RX

1 • Operating frequency:

 

Top

Connect a SINAD meter with an

Minimum distortion

SENSITIVITY

400.000

MHz A

panel

8Ω load to the [SP] jack.

level

[BPF T1] –

440.000

MHz B

 

 

 

[BPF T4]

470.000

MHz C

 

 

 

 

490.000

MHz D, E

 

 

 

Connect a standard signal generator to the antenna connector and set as:

 

 

 

 

 

Frequency

:

400.000 MHz A

 

 

 

 

 

 

 

 

 

 

 

440.000 MHz B

 

 

 

 

 

 

 

 

 

 

 

470.000 MHz C

 

 

 

 

 

 

 

 

 

 

 

490.000 MHz D, E

 

 

 

 

 

 

 

 

 

Level

: 10 µV* (–87 dBm)

 

 

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz*1

 

 

 

 

 

 

 

 

 

 

 

±2.8 kHz ˜

 

 

 

 

 

 

 

 

 

 

 

±1.75 kHz*2 ˆ

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT: The BPF T1–BPF T4 can be adjusted automatically.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-1: Set the cursol to “BPF ALL” on the adjustment program and then push [ENTER]

 

 

 

 

 

 

 

 

key.

 

 

 

 

 

 

 

 

 

 

 

-2: The connected PC tunes BPF T1–BPF T4 to peak levels.

 

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

-1: Set the cursol to one of BPF T1, T2, T3, or T4 as desired.

 

 

 

 

 

 

 

 

 

-2: Push [ENTER] key to start tuning.

 

 

 

 

 

 

 

 

 

-3: Repeat -1 and

-2 to perform additional BPF tuning.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUELCH

1

 

 

• Operating frequency:

Top

Connect a SINAD meter with an

12 dB SINAD

LEVEL

 

 

 

 

 

400.000 MHz A

panel

8Ω load to the [SP] jack.

 

 

[SQL]

 

 

 

 

 

440.000 MHz B

 

 

 

 

 

 

 

 

 

 

470.000 MHz C

 

 

 

 

 

 

 

 

 

 

490.000 MHz D, E

 

 

 

 

 

 

 

 

 

• Connect a standard signal generator to

 

 

 

 

 

 

 

 

 

the antenna connector and set as:

 

 

 

 

 

 

 

 

 

Frequency

:

400.000 MHz A

 

 

 

 

 

 

 

 

 

 

 

440.000 MHz B

 

 

 

 

 

 

 

 

 

 

 

470.000 MHz C

 

 

 

 

 

 

 

 

 

 

 

490.000 MHz D, E

 

 

 

 

 

 

 

 

 

Level

: 0.2 µV* (–121 dBm)

 

 

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz*1

 

 

 

 

 

 

 

 

 

 

 

±2.8 kHz ˜

 

 

 

 

 

 

 

 

 

 

 

±1.75 kHz*2 ˆ

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

• Receiving

 

 

 

 

At the point where

 

 

 

 

 

 

 

 

 

 

the audio signals

 

 

 

 

 

 

 

 

 

 

just appears.

 

 

 

 

 

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

*1, *2W/N-type must be set the standard signal generator deviation level both *1 and *2 on the RX SENSITIVITY AND SQUELCH LEVEL ADJUSTMENTS.

A: 400–430 MHz

B: 440–470 MHz

C: 470–500 MHz

D: 490–512 MHz

E: 490–520 MHz

ˆ: N-type

: W-type

˜: M-type

 

 

5 - 7

Page 57
Image 57
Icom IC-F3GT, IC-F3GS service manual BPF T1