Icom IC-F3GT SOFTWARE ADJUSTMENT - continued, Adjustment Condition, Measurement, Value, Unit

Models: IC-F3GS

1 83
Download 83 pages 55.86 Kb
Page 17
Image 17
SOFTWARE ADJUSTMENT – continued

SOFTWARE ADJUSTMENT – continued

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

ADJUSTMENT

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

RX

1 • Operating frequency:

Top

Connect a SINAD meter with an

Minimum distortion

SENSITIVITY

 

136.000 MHz (L-band)

panel

8Ω load to the [SP] jack.

level

[BPF T1] –

 

146.000 MHz (H-band)

 

 

 

[BPF T4]

• Connect a standard signal generator to

 

 

 

 

the antenna connector and set as:

 

 

 

 

Frequency

: 136.000 MHz (L-band)

 

 

 

 

 

: 146.000 MHz (H-band)

 

 

 

 

Level

: 5.6 µV* (–92 dBm)

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

Deviation

: ±3.5 kHz (W-type)*1

 

 

 

 

 

±2.8 kHz (M-type)

 

 

 

 

 

±1.75 kHz (N-type)*1

 

 

 

Set the NARROW ch. [W/N-type] only

Receiving

 

 

 

 

 

CONVENIENT: The BPF T1–BPF T4 can be adjusted automatically.

 

 

 

 

 

 

 

 

-1: Set the cursol to “BPF ALL” on the adjustment program and then push [ENTER]

 

 

 

 

 

 

 

key.

 

 

 

 

 

 

 

 

 

 

-2: The connected PC tunes BPF T1–BPF T4 to peak levels.

 

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

-1: Set the cursol to one of BPF T1, T2, T3, or T4 as desired.

 

 

 

 

 

 

 

 

-2: Push [ENTER] key to start tuning.

 

 

 

 

 

 

 

 

-3: Repeat -1 and

-2 to perform additional BPF tuning.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUELCH

1

 

 

• Operating frequency:

Top

Connect a SINAD meter with an

12 dB SINAD

LEVEL

 

 

 

 

 

136.000 MHz (L-band)

panel

8Ω load to the [SP] jack.

 

 

[SQL]

 

 

 

 

 

146.000 MHz (H-band)

 

 

 

 

 

 

 

 

 

• Connect a standard signal generator to

 

 

 

 

 

 

 

 

 

the antenna connector and set as:

 

 

 

 

 

 

 

 

 

Frequency

: 136.000 MHz (L-band)

 

 

 

 

 

 

 

 

 

 

146.000 MHz (H-band)

 

 

 

 

 

 

 

 

 

Level

: OFF

 

 

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz (W-type)*1

 

 

 

 

 

 

 

 

 

 

±2.8 kHz (M-type)

 

 

 

 

 

 

 

 

 

 

±1.75 kHz (N-type)*1

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

• Receiving

 

 

 

At the point where

 

 

 

 

 

 

 

 

 

the audio signals

 

 

 

 

 

 

 

 

 

just appears.

 

 

 

 

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.

*1W/N-type must adjust both (W-type) and (N-type).

5 - 7

Page 17
Image 17
Icom IC-F3GT, IC-F3GS SOFTWARE ADJUSTMENT - continued, Adjustment Condition, Measurement, Value, Unit, Location