Icom IC-F51, IC-F50 service manual Preparation

Models: IC-F51 IC-F50

1 38
Download 38 pages 15.56 Kb
Page 14
Image 14

SECTION 5 ADJUSTMENT PROCEDURES

5-1 PREPARATION

When adjusting IC-F60/F61, the optional CS-F50 ADJ ADJUSTMENT SOFTWARE (Rev. 1.0 or later), *OPC-966 JIG CABLE (modified OPC-966 CLONING CABLE) are required.

REQUIRED TEST EQUIPMENT

EQUIPMENT

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

 

 

 

 

 

 

DC power supply

Output voltage

: 7.5 V DC

Audio generator

Frequency range

: 300–3000 Hz

Current capacity

: 5 A or more

Output level

: 1–500 mV

 

 

 

 

 

 

 

 

FM deviation meter

Frequency range

: DC–600 MHz

Attenuator

Power attenuation

: 40 or 50 dB

Measuring range

: 0 to ±10 kHz

Capacity

: 10 W or more

 

 

 

 

 

 

 

 

 

Frequency range

: 0.1–600 MHz

Standard signal

Frequency range

: 300–600 MHz

Frequency counter

Frequency accuracy : ±1 ppm or better

Output level

: 0.1 µV–32 mV

generator (SSG)

 

Sensitivity

: 100 mV or better

 

(–127 to –17 dBm)

 

 

 

 

 

 

 

 

 

Digital multimeter

Input impedance

: 10 M/V DC or better

DC voltmeter

Input impedance

: 50 k/V DC or better

 

 

 

 

 

 

 

Measuring range

: 1–10 W

Oscilloscope

Frequency range

: DC–20 MHz

RF power meter

Frequency range

: 300–600 MHz

Measuring range

: 0.01–20 V

 

(terminated type)

Impedance

: 50

 

 

 

AC millivoltmeter

Measuring range

: 10 mV–10 V

 

SWR

: Less than 1.2 : 1

 

 

 

 

 

 

 

 

 

 

SYSTEM REQUIREMENTS

Microsoft® Windows® 95 or Windows® 98

RS-232C serial port

ADJUSTMENT SOFTWARE INSTALLATION

qBoot up Windows.

- Quit all applications when Windows is running.

wInsert the cloning software CD-ROM into the appropriate CD-ROM drive.

eSelect ‘Run’ from the [Start] menu.

rType the setup program name using the full path name, then push [Enter] key.

(For example; D:\Setup.exe)

tFollow the prompts.

yProgram group ‘CS-F50 ADJ’ appears in the ‘Programs’ folder of the [Start] menu.

STARTING SOFTWARE ADJUSTMENT

qConnect IC-F60/F61 and PC with *OPC-966 JIG CABLE. w Turn the transceiver power ON.

e Boot up Windows, and click the program group ‘CS-F50 ADJ’ in the ‘Programs’ folder of the [Start] menu, then CS-F50 ADJ’s

window appears.

r Click ‘Connect’ on the CS-F50’s window, then appears IC-F60/F61’s up-to-date condition.

t Set or modify adjustment data as desired.

Microsoft and Windows are registered trademarks of Microsoft Corporation in the U.S.A. and other countries.

BEFORE STARTING SOFTWARE ADJUSTMENT

Program the adjustment frequencies, listed in page 5-2, into the transceiver using with the CS-F50 before starting the software adjustment. Otherwise, the transceiver can not start software adjustment.

CAUTION!: BACK UP the originally programed memory data in the transceiver before progaming the adjustment frequencies.

When program the adjustment frequencies into the transceiver, the transceiver’s memory data will be overwritten and lose original mem- ory data at the same time.

5 - 1

Page 14