SOFTWARE ADJUSTMENTS (RECEIVING)

Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.

Need to adjust “S-METER ADJUSTMENT” after “RX SENSITIVITY ADJUSTMENT” is adjusted. Otherwise, “S-METER ADJUSTMENT” will not be adjusted properly.

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

MEASUREMENT

VALUE

 

 

 

 

UNIT

LOCATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RX

 

1

• Operating CH

: CH11

MAIN

Connect a SINAD meter with an

Minimum distortion

SENSITIVITY

 

 

• Connect a standard signal generator to

 

8 load to the multi connector

level

 

[BPF T1],

 

 

the antenna connector and set as:

 

through the JIG cable (*OPC-

 

 

[BPF T2]

 

 

Frequency

: 136.000 MHz

 

966).

 

 

 

 

 

Level

: 10 µV* (–87 dBm)

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONVENIENT:

 

 

 

 

 

 

 

 

The BPF T1, BPF T2 can be adjusted automatically.

 

 

 

 

 

q-1: Set the cursor to “BPF ALL” on the adjustment program and then push [ENTER] key.

 

 

 

 

q-2: The connected PC tunes BPF T1, BPF T2 to peak levels.

 

 

 

 

 

 

or

 

 

 

 

 

 

 

w-1: Set the cursor to one of BPF T1, T2 as desired.

 

 

 

 

 

w-2: Push [ENTER] key to start tuning.

 

 

 

 

 

 

 

w-3: Repeat w-1 and w-2 to perform additional BPF tuning.

 

 

 

 

 

 

 

 

 

S-METER

 

1

• Operating CH

: CH11

Push [ENTER] key on the connected computer keyboard to

[S-METER]

 

 

• Connect an SSG to the antenna con-

set “S6 level”.

 

 

 

 

 

nector and set as:

 

 

 

 

 

 

 

Frequency

: 136.000 MHz

 

 

 

 

 

 

 

Level

: 4.5 µV* (–94 dBm)

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Set an SSG as

:

Push [ENTER] key on the connected computer keyboard to

 

 

 

Level

: 0.25 µV* (–119 dBm)

set “S1 level”.

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

SQUELCH

 

1

• Operating CH

: CH9

Front

Internal speaker

Set “SQL level” to

LEVEL

 

 

• Connect an SSG to the antenna con-

panel

 

close squelch.

[SQL]

 

 

nector and set as:

 

 

Then set “SQL level”

 

 

 

Frequency

: 155.000 MHz

 

 

 

 

 

 

 

at the point

where

 

 

 

Level

: 0.18 µV* (–122 dBm)

 

 

 

 

 

 

 

the audio

signals

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

just appears.

 

 

 

Deviation

: ±3.5 kHz

 

 

 

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.