Icom IC-F51, IC-F50 service manual Connection, JIG Cable, Ptte PTT MIC Mice, Sp+

Models: IC-F51 IC-F50

1 38
Download 38 pages 15.56 Kb
Page 16
Image 16

• CONNECTION

FM

Attenuator

deviation meter

40 dB or 50 dB

RF power meter 0.1–10 W/50

Frequency

counter

Personal computer

to an RS-232C port

DB9 female plug

(incl. level converter circuit)

RS-232C cable (straight)

*OPC-966 (JIG CABLE)

to the antenna connector

IC-F50/F51

*OPC-966

(JIG CABLE)

Standard signal generator

0.1V to 32 mV (–127 dBm to –17 dBm)

CAUTION!

DO NOT transmit while to SSG is connected to the antenna connector

Audio generator

SINAD meter

Speaker (8 )

OPC-966 (Cloning cable)

 

Add a jumper wire here

 

Electrolytic capacity

 

 

47 µF

 

PTTE

 

 

PTT

 

 

MIC

+

 

MICE

Audio generator

AC

 

 

300 Hz to 3 kHz

millivoltmeter

SP–

 

 

SP+

 

 

 

 

 

+

5 - 3