Icom IC-M2A instruction manual Troubleshooting, Problem Possible Cause Solution

Models: IC-M2A

1 32
Download 32 pages 53.44 Kb
Page 29
Image 29

 

 

 

 

9

 

TROUBLESHOOTING

 

 

 

 

 

PROBLEM

POSSIBLE CAUSE

SOLUTION.

REF.

 

 

 

 

 

 

No power comes ON.

• The battery is exhausted.

• Recharge the battery pack.

p. 17

 

 

• Bad connection to the battery pack.

• Check the connection to the transceiver.

p. 3

 

 

 

 

 

 

No sound comes from

• Squelch level is too deep.

• Set squelch to the threshold point.

p. 7

 

the speaker.

• Volume level is too low.

• Set [OFF/VOL] to a suitable level.

p. 8

 

 

• Speaker has been exposed to water.

• Drain water from the speaker.

 

 

 

 

 

 

Transmitting is impossi-

• Some channels are for low power or re-

• Change channels.

pgs. 2, 4

 

ble, or high power can

ceive only.

 

 

 

 

not be selected.

• The battery is exhausted.

• Recharge the battery pack.

p. 17

 

 

• The output power is set to low.

• Push [H/L] to select high power.

p. 2

 

 

 

 

 

 

The display channel

• Lock function is activated.

• Push [H/L•LOCK] for 1 sec. to cancel the

p. 2

 

cannot be changed.

 

function.

 

 

 

 

 

 

 

Scan does not start.

• “TAG” channels are not programmed.

• Set the desired channels as “TAG” channels.

p. 12

 

 

 

 

 

 

No beeps sound.

• Beep tones are turned OFF.

• Set the beep tones to AUTO or 1–10 in SET

p. 13

 

 

 

mode.

 

 

 

 

 

 

 

Self check error.

• Transceiver’s inside temperature is below

• Leave the transceiver at room temperature

 

(Temperature error)

–20°C (–4°F) or above +60°C (+120°F).

for a while. Turn the power ON to check if the

 

 

 

 

internal temperature has returned to normal.

 

 

 

 

 

 

 

Self check error.

• The connected battery pack’s voltage is

• Verify the battery voltage is correct.

 

(Battery voltage error)

more than 11 V.

 

 

 

 

 

 

 

 

 

Self check error.

• Water has entered the transceiver.

• Have the transceiver checked at your local

 

(Water intrusion error)

 

distributor or dealer to see whether the trans-

 

 

 

 

ceiver works properly or not.

 

 

 

 

 

 

 

 

23

Page 29
Image 29
Icom IC-M2A instruction manual Troubleshooting, Problem Possible Cause Solution