During normal scan.

12 COMMANDMIC II™ HM-157

Setting TAG channels

qWhile pushing [H/L], push [CH/WX• DW U/I/C] several

times to select the desired channel group (USA, INT or CAN).

wPush [Y] or [Z] to select the desired channel to be set as a TAG channel.

ePush [SCAN• TAG ] for 1 sec. to set the displayed channel as a TAG channel.

• “ ” appears in the display.

rTo cancel the TAG channel setting, repeat step e.

• “ ” disappears.

Clearing (or setting) all tagged channels

While pushing [H/L], push [SCAN• TAG ] for 3 sec. (until a long beep changes to 2 short beeps) to clear all TAG channels in the channel group.

Repeat above procedure to set all TAG channels.

Starting a scan

Set scan type (Priority or Normal scan) and scan resume timer in advance, using Set mode. (p. 32)

qWhile pushing [H/L], push [CH/WX• DW U/I/C] several

times to select the desired channel group (USA, INT or CAN).

wSet TAG channels as described at left.

eMake sure the squelch is closed to start a scan. r Push [SCAN• TAG ] to start

Priority or Normal scan.

”or “ ” appears at the channel comment indicator during Priority or Normal scan,

respectively.

• When a signal is detected, scan pauses until the signal disap-

pears or resumes after pausing

5 sec. according to the Set mode setting (Channel 16 is still monitored during Priority scan).

Push [Y] or [Z] to check the scanning TAG channels, to change the scanning direction or resume the scan manually.

” blinks at the channel comment indicator and a beep tone sounds when a signal is received on Channel 16 during Priority scan.

tTo stop the scan, repeat step r.

48