Page 3

SPECIFICATIONS

All specifications are warranted unless noted typical and apply to the 61-340 & 61-342

Stated accuracies are at 23°C±5°C at less than 75% relative humidity and without the battery indicator displayed.

General specifications

Characteristics

Description

 

 

 

Display count

3 3/4 digit liquid crystal display, max count 4000

 

 

 

Numeric update rate

2.5 times / sec

 

 

 

 

Polarity display

Automatic

 

 

 

 

Over range display

“OL” is displayed

 

 

 

 

Low battery indicator

is indicated

 

 

 

Automatic power-off time

Automatic power off ≈ 10minutes

 

 

Power source

9.0V battery: types- NEDA 1604, JIS006P, IEC6F22

for both 61-340 and

61-342

 

 

 

*Maximum input voltage

1000Vrms CAT III between V and COM

 

 

*Maximum floating voltage

1000Vrms CAT III between any terminal and earth ground

 

 

Maximum input current

400mA between µA /mA and COM

 

 

Overload protection mA connector

500mA (250V) fast blow fuse.

 

 

Overload protection 10A connector

10A (250V) fast blow fuse.

 

 

 

V connector

V , V , , ,

, , Hz

 

 

 

µA /mA connector

µA, mA, Temp

 

 

 

Temperature Coefficient

0.1×(Spec. Accuracy) per °C, <18°C or >28°C

 

 

Battery Life

Alkaline 9V, ≈ 200 hours for 61-340

Alkaline 9V, ≈ 150 hours for 61-342

 

 

 

 

Form Number TM61340-2

Rev 2 November 2007

Page 5
Image 5
IDEAL INDUSTRIES 61-340 technical manual Specifications, General specifications Characteristics Description