Page 4
Measurement Characteristics
Accuracy is ±(% reading + number of digits) at 23°C ± 5°C, less than 75% R.H.
(1) DC Volts(for
| Range | Resolution | Accuracy | Over voltage |
| protection | |||
|
|
|
| |
|
|
|
|
|
| 400.0mV | 0.1mV | ±(0.8% reading + 3 digits) |
|
| 4.000V | 1mV |
|
|
| 40.00V | 10mV | ±(0.8% reading + 1 digits) | 1000VDC or 750VAC |
|
|
|
|
|
| 400.0V | 100mV |
|
|
| 1000V | 1V | ±(1.0% reading + 3 digits) |
|
Input Impedance: 10MΩ |
|
| ||
(2) AC Volts |
|
| ||
|
|
|
|
|
| Range | Resolution | Accuracy | Over voltage |
| protection | |||
|
|
|
| |
| 400.0mV | 0.1mV | ±(1.2%+8) |
|
| 4.000V | 1mV |
|
|
|
|
|
| 1000VDC or 750VAC |
| 40.00V | 10mV | 1.0% + 5 | |
|
|
|
|
|
| 400.0V | 100mV |
|
|
| 750V | 1V | ±(1.2%+5) |
|
Input Impedance: 10MΩ
AC Conversion Type:
Crest Factor: C.F. = Peak/RMS
For
Frequency response: 40~400Hz
(3a) DC |
| |||
|
|
|
|
|
| Range | Resolution | Accuracy | Input Protection |
| 400.0µA | 0.1μA | ±(0.8% reading + 2 digits)* |
|
| 4000µA | 1μA | 500mA, 250V Fast | |
|
| |||
| 40.00mA | 10μA | ±(0.8% reading + 3 digits)* | Blow Fuse |
| 400.0mA | 0.1mA |
| |
|
|
|
Overload Protection: mA Input: 500mA, 250V Fast Blow fuse.
Form Number | Rev 2 November 2007 |