ASSEMBLY

4.3 Electrical Connections

The connecting cables may be brought inside the boiler through

The electrical wiring has been carefully checked in the factory and

the cut-outs provided in the cover of the boiler, which may be used

along with purchased cable channels.

the internal connections of the control panel must not be modified

Fasten the cables to the rear plate of the control panel by means of

in any event.

The electrical connections of the boiler shall be made in compliance

the cable clamps (supplied in the instructions bag), after mounting

them on the plate.

with applicable standards and regulations in force.

The pump cable has a connector fitted. Discard the connector.

The unit shall be powered by a circuit with an omnipole switch with

 

an opening distance greater than 3 mm.

WARNING

 

WARNING

VERY IMPORTANT: never place sensor cables

Electrical connections shall be carried out by a

(extra low voltage) and 230 V power supply cables

in the same cable channel or duct.

qualified professional only.

 

 

All the connections shall be made to the connection strip provided

 

for that purpose outside the volume of the control panel.

Refer to Boiler Assembly Instructions for Control Panel Installation

￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿

 

￿￿￿￿￿￿￿

4.4 Installation with MB1 Domestic Hot water Priority and Regulation Mode

Fitting and Connecting the MB1 Module

Fit the MB1 module on the front of the control panel. Proceed as follows:

1. Remove the cover: cut the four fixing studs of the cover with a knife and fold it outward.

2. Install and connect the MB1 module as directed on pages 16-18.