Installation

Installation

The following instructions should be read by a qualified technician to ensure that the appliance is installed, regulated and technically serviced correctly in compliance with current regulations.

Important: disconnect the cooker from the electricity when making any adjustement, maintenance operation, etc.

Positioning

The appliance can be installed next to furniture units which are no taller than the top of the cooker hob. For proper

400V 3N~

1

H05RR-F 5x2.5 CEI-UNEL 35363

R

400V 2N~

1

H05RR-F 4x2.5 CEI-UNEL 35363

 

 

 

230V 1N~

 

 

 

 

1

H05RR-F 3x4 CEI-UNEL 35363

R

 

 

 

2 3 4

S

T

 

2

3

4

R

S N

 

2

3

4

 

N

 

5

Positioning N

5

5

installation of the cooker, the following precautions must be taken:

a)Kitchen cabinets installed next to the cooker that are taller than the top of the hob must be situated at least 200 mm from the edge of the hob.

b)Hoods must be installed according to the requirements in the installation manual for the hoods themselves and in any case at a minimum distance of 650 mm.

c)Place the wall cabinets adjacent to the hood at a minimum height of 420 mm from the hob (see figure).

d)Should the cooker be installed beneath a wall cabinet, the latter should be situated at least 700 mm (millimetres) away from the hob, as shown in the figu- re.

e)the cut-out for the cooker cabinet should have the dimensions indicated in the figure.

Feeding cable installation

Terminal block opening:

Unscrew screw “V” (Fig. C)

Pull and open the junction block lid

For the installation of the feeding cable carry out the following operations:

position the small connection A-Baccording to the type of connection that has to be performed using the scheme shown in the figure D.

Note: the small connections are prepared by the Factory for the 230V monophase connection (contacts 1-2-3 are connected to one another). The bridge 4-5 is situated in the lower part of the terminal block.

introduce the cables (N and $) as shown in the figure and tighten the relative screws.

fix the remaining cables on the 1-2-3 clips.

fix the feeding cable in the special cable stop and close the cover fastening it with the screw “V”.

HOOD

 

Min. 600mm.

min. 650 mm. with hood min. 700 mm. without hood

Min. 420mm.

Min. 420mm.

Levelling your appliance (only on a few models)

V

2

3

1

 

 

B

N

A

 

Your cooker is supplied with feet for levelling the appliance. If necessary, these feet can be screwed into the housings in the corners of the cooker base (Fig. A).

Mounting the legs (only on a few models)

Press-fit legs are supplied which fit under the base of your cooker (Fig. B).

Fig. A

Fig. B

Electrical connection

The power supply cable since its size depends on the electric connection (see the following connection diagram).

Fig. C

Fig. D

Connecting the supply cable to the mains

Fit a plug, normalised for the load indicated on the data plate, on the cable; when making the connection directly to the mains, an omnipoIar switch with a minimum opening of 3 mm between the contacts, must be installed between the appliance and the mains.This switch must be sufficient for the load and must comply to regulations in force (the earthing wire must not be interrupted by the switch). The power supply cable must be positioned so that it does not exceed 50°C more than room temperature at any point of its length. Before making the connection check that:

the limiter valve and the home system can support the appliance load (see data plate);

the power supply system has an efficient earthing connection which complies with the provisions of current regulations;

the socket or omnipoar circuit-breaker is easily accessible once the cooker has been installed.