TROUBLESHOOTING

SYMPTOM

POSSIBLE SOLUTIONS

No power

• Verify the power cord is properly connected to the power outlet and to

 

the monitor.

 

• Verify the power switch is ON and that the Power button on the remote or

 

keypad has been turned on (the front LED should be white).

 

• Plug another electrical device to the power outlet to verify that the outlet is

 

supplying the proper voltage.

 

 

The monitor shuts down suddenly

• Check the Sleep Timer setting in the Configuration 2 OSD menu. Disable the

 

Sleep Timer.

 

• Verify that a source is active.

 

• The monitor may have overheated. Remove any objects blocking the vents.

 

• Review the Windows power settings of the monitor.

 

 

No image

• If attempting to display an external source, see “No image from external

 

source” below.

 

• Verify that the monitor is turned on (the front LED should be white).

 

 

No image from external source

• Verify that the source is correct by reviewing the Settings>Input Source menu.

 

• Verify that connections between the source and the monitor have been

 

made correctly.

 

• Verify that the cables are in good condition.

 

• Verify the correct input source is selected and that the input signal is

 

compatible with the monitor.

 

 

The colors on the monitor do not

• Adjust the color settings in the Picture menu.

look right

• Reset the picture settings.

 

 

• Verify that connections between the source and the monitor have been made

 

correctly.

 

• Verify that the cables are in good condition.

No touchpad activity with

• Verify that the USB B to USB type A cable is plugged from the laptop into the

external computer

monitor correctly.

 

• Verify that the laptop’s operating system is Windows® 7 or 8. (The monitor

 

touchpad does not support any other operating systems.)

 

 

Touchpad functions are not

• Remove all objects placed on the lip of the monitor and/or within 2” of the

functioning consistently

touchpad screen.

 

• Disable the PiP feature.

 

• Power the device off and back on after a few seconds. Re-booting the device

 

helps the touchpad to re-synchronize.

 

• Run the Calibration Tool (See "Calibration Tool" on page 30).

 

 

Remote is not working

• Make sure the batteries are installed in the proper orientation and are not dead.

 

• Verify the remote is turned on (the button is on the bottom of the remote).

 

• Verify you are pointing the remote at the table and are within 26’ (8m) and 30

 

degrees (horz/vert) of the sensor.

 

• Verify that the IR Control setting in the Advanced Option OSD menu is set

 

to Normal.

 

 

INF7001a Hardware Guide

Page 21

Page 23
Image 23
InFocus INF7001A manual Troubleshooting, Symptom Possible Solutions