Cleaning Instructions
PERSONAL INJURY
Wait until auger paddles stop before cleaning Waste Xpress.
1.Press stop button on control center to stop system (disposer & Waste Xpress).
2.Holding both handles remove discharge chute by . tilting it upward (see Figure 25).
3.Remove
4.Lift auger and screen up and then out . (see Figure 26).
5.Remove auger from screen by lifting it up and out (see Figure 28).
6.Rinse auger, screen, auger compartment and . discharge chute. Auger, screen and discharge . chute are dishwasher safe and should be washed daily. Flush inlet and outlet with a fresh water . supply to keep the drain lines clean.
7.Install auger into screen then place screen .
over drive.
8.Ensure that the auger drops into position.
9.Secure bearing bracket with captive fasteners.
10.Install discharge chute by placing bottom, front . portion in first and then tilting back and downward.
Discharge |
Chute |
Figure 25.
Captive |
Fasteners |
Auger Screen |
Figure 26.
Figure 27. Bearing Bracket
Figure 28.
17