Warranty
WASTE XPRESS SYSTEM LIMITED WARRANTY
The InSinkErator® Waste Xpress®, disposer and control centers are warranted against defects in material and workmanship for one year from the date of installation. The warranty includes parts and labor, provided an . InSinkErator Factory Authorized Service Center performs the service. This warranty does not apply if the failure . is due to: faulty or improper electrical installation, faulty or improper plumbing installation, product abuse or . misuse, accidental damage, clogged drain lines, improperly sized unit (as specified by InSinkErator).
Introduction/Typical Installation
INTRODUCTION
The InSinkErator® Waste Xpress® is a Foodservice kitchen waste reduction system that utilizes a standard Foodservice disposer in line with the Waste Xpress . dewatering system. The kitchen waste is ground through the disposer then transferred to the Waste Xpress where it is compressed. After the waste is . compressed, the liquids are sent down the drain line and the solid waste exiting the Waste Xpress is 85% less in volume (see Figure 1 for typical installation).
Important – These installation instructions are for the benefit of the installing contractor. InSinkErator and/or InSinkErator Factory Authorized Service Centers do not make original installations. For technical information not covered in these instructions, contact the supplier, an InSinkErator Field Sales Representative, or InSinkErator Foodservice Sales and Service at
TYPICAL INSTALLATION
A typical Waste Xpress installation incorporates the following connections (see Figure 1):
•Waste Xpress
•Disposer
•Control Center
•Syphon breaker
•Solenoid valves (2)
•Water shut off valve
•Bowl or trough
•Flow control valve
•Cold water (sink or trough)
•Hot water (Waste Xpress)
| Syphon Breaker |
|
|
| |
Sink Bowl |
| Cold Water Solenoid | Hot Water Solenoid | Waste Xpress | |
|
|
|
| 1" min | |
|
| (38.1 mm |
|
| |
|
| min) |
|
| (25.4 mm min) |
Disposer |
|
|
|
|
|
|
| Flow Control Valve | Shut Off Valve |
|
|
|
|
|
|
| |
|
|
| (supplied |
|
|
|
| by others) |
|
| |
|
|
|
|
| |
|
| 10 max |
|
|
|
|
| (3.1 m max) |
|
|
|
Figure 1. Typical Installation
4