15-42 Vol. 3
MACHINE-CHECK ARCHITECTURE
When machine-check exceptions are enabled for the Pentium processor
(MCE flag is set in c ontrol re gister CR4), the machine-check exception
handler uses the RDMSR instruction to read the error type from the
P5_MC_TYPE register and the machine check address from the
P5_MC_ADDR register. The handler then normally reports these register
values to the system console before aborting execution (see Example 15-2).

15.10.3 Logging Correctable Machine-Check Errors

The error handling routine for servicing the machine-check exceptions is
responsible for logging uncorrected errors.
If a machine-check error is correctable, the processor does not generate a
machine-check exception for it. To detect correctable machine-check errors,
a utility program must be written that reads each of the machine-check
error-reporting register banks and logs the results in an accounting file or
data structure. This utility can be implemented in either of the following
ways.
•A system daemon that polls the register banks on an infrequent basis, such as
hourly or daily.
•A user-initiated application that polls the register banks and records the
exceptions. Here, the actual polling service is provided by an operating-system
driver or through the system call interface.
•An interrupt service routine servicing CMCI can read the MC banks and log the
error.
Example 15-3 gives pseudocode for an error logging utility.
Example 15-3. Machine-Check Error Logging Pseudocode
Assume that execution is restartable;
IF the processor supports MCA
THEN
FOR each bank of machine-check registers
DO
READ IA32_MCi_STATUS;
IF VAL flag in IA32_MCi_STATUS = 1
THEN
IF ADDRV flag in IA32_MCi_STATUS = 1
THEN READ IA32_MCi_ADDR;
FI;
IF MISCV flag in IA32_MCi_STATUS = 1
THEN READ IA32_MCi_MISC;
FI;
IF MCIP flag in IA32_MCG_STATUS = 1
(* Machine-check exception is in progress *)