3
Optional Information

How to Change Port 1

from MDI-X to MDI

All ports on the switch are MDI-X.
Press the MDI/MDI-X button to change
Port 1 to MDI so you can connect to
another switch or hub using a straight-
through cable.
1234
MDI
MDI-X
Intel® Express 410T Standal
o
4
MDI/MDI-X
button
English
MDI
MDI-X

Access the

Configuration Screen

5
Connect your PC to the Management
module’s serial port using the null-modem
cable (included).
Set a VT100-compatible terminalemula-
tion program (such as HyperTerminal*) to
these parameters:
- 9600 baud - 8 data bits
- No parity - 1 stop bit
- No flow control
Press E to connect to the Configura-
tion screen.
Navigate the menus with these keys:
TMove to next item.
BMove to previous item.
zToggle options within a field.
c + SSave changes to configuration.
c + RRepaint the screen.
<Auto> is the default setting for the ports.
You only need to configure the port
settings if you are having difficulty
connecting to a device.
Configuration Screen: Items surrounded by angle
brackets < > indicate a toggle field. Use the z to
toggle selections.
Speed Auto =all port settings are
automatically negotiated.
100 = port set to 100Mbps.
10 = port set to 10Mbps.
Duplex Half = port set to half duplex.
Full =port set to full duplex.
– = port set to auto mode.
Flow enable =Flow control is enabled in full
Control duplex mode. Back pressure is
enabled in half duplex mode.
disable = flow control is off.
– = port set to auto mode.