20 ISP2150 2U Rack Server Platform Product Guide
The EMP Console uses three management plug-ins to monitor the server:
SEL Viewer
SDR Viewer
FRU Viewer
The EMP Console also has Phonebook plug-in that can be used to create and maintain a list of
servers and their phone numbers.
NOTE
EMP and PEP (Platform Event Paging) share your modem. PEP has priority
over all applications except EMP. If an alert occurs, PEP will reset your
modem and page you.

Platform Event Paging

With Platform Event Paging (PEP), your server can be configured to automatically dial up a paging
service and page you when a platform event occurs. Platform events include temperature
out-of-range, voltage out-of-range, chassis intrusion, fan failure, etc.
If PEP is enabled and the BMC receives or detects a new event, it automatically sends a page. It
can send a page if the processors are down or if the system software is unavailable.
PEP needs an external modem connected to the server’s EMP (Emergency Management Port) serial
connection. This is typically the COM2 serial connector.
Software Security
The BIOS Setup and the System Setup Utility (SSU) provide a number of security features to
prevent unauthorized or accidental access to the system. Once the security measures are enabled,
you can access the system only after you enter the correct password(s). For example:
Enable the keyboard lockout timer so that the server requires a password to reactivate the
keyboard and mouse after a specified time out period1 to 120 minutes.
Set and enable an administrative password.
Set and enable a user password.
Set secure mode to prevent keyboard or mouse input and to prevent use of the front panel reset
and power switches.
Activate a hot key combination to enter secure mode quickly.
Disable writing to the diskette drive when secure mode is set.
Disable access to the boot sector of the operating system hard disk drive.