Intel Netstructure MPRTM0020 Rear Transition module manual Alignment Blocks, 9 ADM1026 Controller

Models: Netstructure MPRTM0020 Rear Transition module MPRTM0020

1 44
Download 44 pages 55.67 Kb
Page 25
Image 25

Module Components

AP3[x] indicates that these T1/E1 signals are routed from PMC 3.

Table 12.

RTM Connector (Zone 3) P33 Pinout

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin

 

A

B

C

D

E

F

G

H

 

 

 

 

 

 

 

 

 

1

AP3[0]TX+

AP3[1]TX-

AP3[0]RX+

AP3[0]RX-

AP3[1]TX+

AP3[1]TX-

AP3[1]RX+

AP3[1]RX-

 

 

 

 

 

 

 

 

 

2

AP3[2]TX+

AP3[2]TX-

AP3[2]RX+

AP3[2]RX-

AP3[3]TX+

AP3[3]TX-

AP3[3]RX+

AP3[3]RX-

 

 

 

 

 

 

 

 

 

3

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

4

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

5

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

6

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

7

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

8

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

9

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

10

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

No Connect

 

 

 

 

 

 

 

 

 

 

4.3.8Alignment Blocks

The MPRTM0020 Rear Transition Module implements the rK1 and A2 alignment blocks at the top of Zone 2 and Zone 3, as required in Section 2.4.4 of the PICMG 3.0 Specification. The Zone 2 alignment block (rK1) is assigned a keying value of 11, and uses Tyco* 1-1469373-1 (or equivalent). The Zone 3 alignment block (A2) is assigned a keying value of 7-3, and uses Tyco 7-1469373-3 (or equivalent).

4.3.9ADM1026 Controller

The RTM has an ADM1026 controller that collects sensor information from the board using the SMBus interface. It also has memory to store FRU and user information.

The ADM1026 is managed by the MPCBL0020 Single Board Computer IPMC connected via the I2C bus. These I2C signals are routed from the SBC IPMC through the P30 connector on the Zone 3.

The SBC IPMC communicates with the ADM1026 using an I2C address of 0x5C. From the Shelf management perspective, the RTM can be managed using the IPMB address fronted by the SBC (MPCBL0020) with a FRU Device ID of 0x04.

Refer Section 5 for further information regarding management of the FRU and SDR data of the RTM.Table 13 shows mapping between GPIO signal name and pin on the ADM1026.

Table 13. GPIO Signal Mapping (Sheet 1 of 2)

GPIO Signals

Pin on ADM1026

 

 

Hotswap_Switch

3

 

 

OOS Green LED Control

6

 

 

OOS Red LED Control

5

 

 

Health Green LED Control

10

 

 

Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006

25

Page 25
Image 25
Intel Netstructure MPRTM0020 Rear Transition module Alignment Blocks, 9 ADM1026 Controller, Gpio Signal Mapping Sheet 1