Upgrading 49
9. Position the retention clip over the plastic tab and engage the retention clip end-slot over the
plastic tab (see 1 in Figure 31). Note that the slot in the clip provides room for side-to-side
motion while engaging the retention clip slots located at each end.
10. Press downward on the retention clip ends over the plastic tabs on the retention bracket (see 2
in Figure 31).
11. Install two retention clips on each processor you install.
OM14368
2
2
1
Figure 31. Attaching the Heat Sink and Retention Clip
Installing the Processor Wind Tunnel
The following instructions apply to the Intel SC5200 Base Server Chassis and reference chassis
installations. If you are installing your server board in the Intel SC5200 Hot-Swap, Redundant
Power Server Chassis, DO NOT install the processor wind tunnel. The ducting in the Intel SC5200
Hot-Swap, Redundant Power Server Chassis eliminates the need for a processor wind tunnel.
1. Install processor wind tunnel center section over the heat sink / processor assembly. Note that
plastic tabs engage the tabs on the retention clips.
OM14369
Figure 32. Attaching the Wind Tunnel Assembly