P/N: 900-10004-00 REV 02 USER GUIDE, IOSAFE R4
83
Note
Enabling disk spin-down will disable journal mode. Once enabled, if you
decide to disable disk spin-down, you will need to manually re-enable
journal mode if desired. A UPS is recommended if you utilize this option.
POWER TIMER
The ioSafe R4 can be scheduled to power off and power back on automatically. Select the
Enable
power timer
checkbox and enter the desired action and time.
Note
When the ioSafe R4 is powered off, any file transfers and backup jobs will
be interrupted, and backup jobs scheduled during the power off state will
not be run.
UPS CONFIGURATION
If this device is sharing a UPS with another ioSafe R4 system, but not directly monitoring the battery
status through a USB connection, you may elect to
Enable monitoring of UPS physically
attached to a remote ReadyNAS
. To use this feature, check the box and enter the IP Address in
the
Remote IP address
field of the ioSafe R4 system that is monitoring the UPS battery status.
As an option, the ioSafe R4 can remotely monitor the UPS when connected to a PC running
Network UPS Tools (NUT). For more information about NUT, see
http://www.networkupstools.org/.