INSTALLATION
Automatic Drain Valve Installation (Optional)
Important Note About Tank Drain Selection:
Jacuzzi Whirlpool Bath strongly recommends purchasing and installing the optional Automatic Drain Valve for the steam generator. This valve prevents standing water from remaining in the tank between uses.
This valve must be installed where the steam generator may be exposed to freezing temperatures, e.g., in seasonal- use homes. This valve automatically drains the tank when the water has cooled.
POWER ENTRY
HOLE B
BUSHING C (PROVIDED)
OPTIONAL AUTOMATIC DRAIN VALVE ASSEMBLY
TB2 |
FITTING A 1/2 NPT (PROVIDED)
1. | Apply thread compound sparingly to male threads | ALTERNATE VERTICAL |
| on fitting A. (Keep thread compound from entering | AUTOMATIC DRAIN |
| the valve.) | VALVE INSTALLATION |
2. | Using a backup wrench to hold fitting A, thread |
|
| valve assembly onto fitting and tighten. Valve |
|
| outlet must point as shown. |
|
3. | Make certain power is disconnected. Remove |
|
| top cover. |
|
4. | Remove and discard plug from hole B . |
|
5. | Feed through hole B. Connect to terminal block 2 |
|
| (TB2) on circuit board. |
|
6. | Locate strain relief bushing C. Snap strain relief |
|
| bushing C into hole B. |
|
7. | Replace cover. |
|
8