Jacuzzi SteamPro manual Automatic Drain Valve Installation Optional, outlet must point as shown

Models: SteamPro

1 22
Download 22 pages 48.97 Kb
Page 10
Image 10
Automatic Drain Valve Installation (Optional)

INSTALLATION

Automatic Drain Valve Installation (Optional)

Important Note About Tank Drain Selection:

Jacuzzi Whirlpool Bath strongly recommends purchasing and installing the optional Automatic Drain Valve for the steam generator. This valve prevents standing water from remaining in the tank between uses.

This valve must be installed where the steam generator may be exposed to freezing temperatures, e.g., in seasonal- use homes. This valve automatically drains the tank when the water has cooled.

POWER ENTRY

HOLE B

BUSHING C (PROVIDED)

OPTIONAL AUTOMATIC DRAIN VALVE ASSEMBLY

TB2

FITTING A 1/2 NPT (PROVIDED)

1.

Apply thread compound sparingly to male threads

ALTERNATE VERTICAL

 

on fitting A. (Keep thread compound from entering

AUTOMATIC DRAIN

 

the valve.)

VALVE INSTALLATION

2.

Using a backup wrench to hold fitting A, thread

 

 

valve assembly onto fitting and tighten. Valve

 

 

outlet must point as shown.

 

3.

Make certain power is disconnected. Remove

 

 

top cover.

 

4.

Remove and discard plug from hole B .

 

5.

Feed through hole B. Connect to terminal block 2

 

 

(TB2) on circuit board.

 

6.

Locate strain relief bushing C. Snap strain relief

 

 

bushing C into hole B.

 

7.

Replace cover.

 