INSTALLATION
5. INSTALL GENERATOR CONTROL |
|
|
|
The low voltage control can be mounted directly to a |
|
|
|
finished wall either inside or outside the steam room. | TEMPERATURE SENSOR |
| |
Using a 2" hole saw, drill a hole in the finished wall where |
| ||
PLUG (J4) |
|
| |
the control is to be mounted (the control cable should | OPTIONAL AUTOMATIC |
|
|
already be | DRAIN CONNECTION |
|
|
|
|
| |
cable, pull it out through the 2" hole and plug it into the |
| SK1 |
|
connector on the back of the control housing. With the |
| SK4 |
|
|
| SK3 |
|
decorative cover removed, screw the two 3" control | TB2 |
|
|
| J4 |
| |
housing mounting screws 1/4" into the mounting bracket. |
|
| |
|
| STEAM | |
See diagram. Run a bead of 100% silicon caulk in- |
|
| |
| STEAM CONTROL PLUGS | CONTROL | |
between the 2 ridges around the perimeter on the back |
| PRIMARY (SK1) 30 MINUTE TEMP (1 BUTTON) |
|
|
|
| |
of the control housing. See diagram. Insert the mounting |
| PRIMARY (SK3) DIGITAL (2 BUTTON) |
|
| SECONDARY (SK4) SECOND DIGITAL |
| |
bracket into the wall cavity by first pushing with the control |
|
| |
|
|
| |
housing and then with a hard flat surface on the control |
|
|
|
housing mounting screws which extend out through the |
|
| TEMPERATURE |
control face. Once the mounting bracket has been |
|
| |
|
| SENSOR | |
|
|
|
inserted into the finished wall, center the control and
tighten the mounting screws to draw the control housing securely against the finished wall. Do not over tighten the mounting screws. Install the decorative cover plate by sliding the top of the cover plate over the tab on the top of the control housing and pushing on the bottom of the cover plate to complete the snap fit. See diagram. Route the generator end of the control cable through the generator hole marked CONTROL WIRING ENTRY using the strain relief provided. Plug the control cable into the connector on the printed circuit board assembly. Insert cable into connector SK1 if a 30 minute temperature control is used or connector SK3 if a digital control is used. See diagram.
6. OPTIONAL SECONDARY GENERATOR CONTROL
As an option, a second digital control can be installed with a generator to provide ON/OFF control both inside and outside the steam room. The second control should be installed as described in paragraphs 1 & 5, with the second control cable plugged into connector SK4 for the digital control on the printed circuit board assembly. See diagram.
WALL | SILICONE | |
CAULK | ||
|
TEMPERATURE
SENSOR
7. INSTALL TEMPERATURE SENSOR
PROBE MUST BE POINTED DOWN
The temperature sensor should be mounted 6" below the SENSOR | PIGTAIL | |
ceiling, inside the steam room, but not directly over the | CABLE | OPTIONAL |
| TRIM RING | |
steam dispersion head or more than 7 feet above the |
| 7/8" HOLE |
floor. Using a 7/8" hole saw, drill a hole in the finished |
|
|
wall where the sensor is to be mounted (the sensor cable |
|
|
should already be |
|
|
sensor cable, pull it out through the hole and plug it into |
|
|
the temperature sensor. It is best to tape the sensor and cable connection together to avoid disconnection inside the wall. Apply silicon caulk as shown in diagram and insert the sensor in the hole. An optional trim ring is included with the sensor. If the 7/8" hole is jagged or is cut too large the trim ring may be used to cover the exposed edges. See diagram. Make sure that the sensor probe is pointing down once installed. Tape the sensor in place while the silicone hardens. Route the generator end of the sensor cable through the generator hole marked CONTROL WIRING ENTRY using the control cable strain relief. Plug the sensor cable into the connector marked J4 on the printed circuit board assembly. See diagram.
12