Jacuzzi SteamPro Install Generator Control, Optional Secondary Generator Control, Installation

Models: SteamPro

1 22
Download 22 pages 48.97 Kb
Page 14
Image 14
5. INSTALL GENERATOR CONTROL

INSTALLATION

5. INSTALL GENERATOR CONTROL

 

 

 

The low voltage control can be mounted directly to a

 

 

 

finished wall either inside or outside the steam room.

TEMPERATURE SENSOR

 

Using a 2" hole saw, drill a hole in the finished wall where

 

PLUG (J4)

 

 

the control is to be mounted (the control cable should

OPTIONAL AUTOMATIC

 

 

already be roughed-in to this location). Locate the control

DRAIN CONNECTION

 

 

 

 

 

cable, pull it out through the 2" hole and plug it into the

 

SK1

 

connector on the back of the control housing. With the

 

SK4

 

 

 

SK3

 

decorative cover removed, screw the two 3" control

TB2

 

 

 

J4

 

housing mounting screws 1/4" into the mounting bracket.

 

 

 

 

STEAM

See diagram. Run a bead of 100% silicon caulk in-

 

 

 

STEAM CONTROL PLUGS

CONTROL

between the 2 ridges around the perimeter on the back

 

PRIMARY (SK1) 30 MINUTE TEMP (1 BUTTON)

 

 

 

 

of the control housing. See diagram. Insert the mounting

 

PRIMARY (SK3) DIGITAL (2 BUTTON)

 

 

SECONDARY (SK4) SECOND DIGITAL

 

bracket into the wall cavity by first pushing with the control

 

 

 

 

 

housing and then with a hard flat surface on the control

 

 

 

housing mounting screws which extend out through the

 

 

TEMPERATURE

control face. Once the mounting bracket has been

 

 

 

 

SENSOR

 

 

 

inserted into the finished wall, center the control and

tighten the mounting screws to draw the control housing securely against the finished wall. Do not over tighten the mounting screws. Install the decorative cover plate by sliding the top of the cover plate over the tab on the top of the control housing and pushing on the bottom of the cover plate to complete the snap fit. See diagram. Route the generator end of the control cable through the generator hole marked CONTROL WIRING ENTRY using the strain relief provided. Plug the control cable into the connector on the printed circuit board assembly. Insert cable into connector SK1 if a 30 minute temperature control is used or connector SK3 if a digital control is used. See diagram.

6. OPTIONAL SECONDARY GENERATOR CONTROL

As an option, a second digital control can be installed with a generator to provide ON/OFF control both inside and outside the steam room. The second control should be installed as described in paragraphs 1 & 5, with the second control cable plugged into connector SK4 for the digital control on the printed circuit board assembly. See diagram.

WALL

SILICONE

CAULK

 

TEMPERATURE

SENSOR

7. INSTALL TEMPERATURE SENSOR

PROBE MUST BE POINTED DOWN

The temperature sensor should be mounted 6" below the SENSOR

PIGTAIL

ceiling, inside the steam room, but not directly over the

CABLE

OPTIONAL

 

TRIM RING

steam dispersion head or more than 7 feet above the

 

7/8" HOLE

floor. Using a 7/8" hole saw, drill a hole in the finished

 

 

wall where the sensor is to be mounted (the sensor cable

 

 

should already be roughed-in to this location). Locate the

 

 

sensor cable, pull it out through the hole and plug it into

 

 

the temperature sensor. It is best to tape the sensor and cable connection together to avoid disconnection inside the wall. Apply silicon caulk as shown in diagram and insert the sensor in the hole. An optional trim ring is included with the sensor. If the 7/8" hole is jagged or is cut too large the trim ring may be used to cover the exposed edges. See diagram. Make sure that the sensor probe is pointing down once installed. Tape the sensor in place while the silicone hardens. Route the generator end of the sensor cable through the generator hole marked CONTROL WIRING ENTRY using the control cable strain relief. Plug the sensor cable into the connector marked J4 on the printed circuit board assembly. See diagram.