INSTALLATION
GENERAL INSTRUCTIONS FOR TEMPERATURE CONTROL MODELS
1. Control Cable |
|
| |
The low voltage control can be mounted up to 25 |
|
| |
feet from the generator either inside or outside the |
|
| |
steam room, also see #6 optional secondary digital |
|
| |
generator control. String the 25' cable from the | 6" MIN - | TEMPERATURE | |
control location through 1/2" holes in the wall studs | |||
| SENSOR | ||
or ceiling joists to the generator. Note: Do not staple |
| STEAM | |
through or damage cable. Use factory supplied |
| CONTROL | |
cables only. Optional for tile rooms, a 1 gang rough- |
| TEMPERATURE | |
in box may be installed at the desired control | 7' | ||
SENSOR | |||
MAX | |||
mounting location. A mounting plate with proper 2" | CABLE | ||
| CONTROL | ||
diameter hole is included with the control kit. Tile up |
| ||
| CABLE | ||
to the 2" hole in the mounting plate. |
| ||
|
| ||
2. Temperature Sensor |
|
| |
It is recommended that the sensor be mounted in |
|
| |
the steam room 6" from the ceiling, but not directly |
|
| |
over the steam dispersion head or more than 7 feet |
|
| |
above the floor. String the sensor cable from the |
|
| |
sensor location through 1/2" holes in the wall studs |
|
| |
or ceiling joists to the generator location. Leave 12" |
|
| |
|
|
of slack at the sensor location. Note: Do not staple through or damage cable. Use factory supplied cables only.
3. Electrical Rough-in
Size wire for the generator as indicated by the Electrical Information Chart on page 4. Use correct size and type to meet electrical codes. Leave 4 feet of slack wire at generator location for finish hookup. Connect the generator to a dedicated circuit breaker. A GFI device is not required by UL. One may be installed if required by local codes or the owner. A GFI device will tend to nuisance trip due to heater element aging.
4. Electrical finish
Materials (locally available):
-3/4" Strain relief for supply wire.
A.Route the copper supply wire with appropriate strain relief through the hole marked POWER ENTRY.
B.Connect the supply wires to the terminal block marked L1 and L2.
C.Connect the ground to the ground lug.
MOUNTING |
|
BRACKET |
|
CONTROL | WALL |
HOUSING |
|
| DECORATIVE |
| CONTROL COVER |
| PLATE |
|
| CONTROL |
|
| HOUSING |
2" DIAMETER |
|
|
HOLE IN FINISHED |
| CONTROL |
WALL |
| |
| HOUSING | |
|
| |
CONTROL HOUSING |
| SEALANT |
MOUNTING SCREWS | DECORATIVE CONTROL | (MUST FILL GROUT |
(DO NOT OVER | COVER PLATE | LINE FOR TILE |
TIGHTEN) |
| WALLS). |
11