GENERAL INSTRUCTIONS FOR TEMPERATURE CONTROL MODELS

INSTALLATION

GENERAL INSTRUCTIONS FOR TEMPERATURE CONTROL MODELS

1. Control Cable Rough-in

 

 

The low voltage control can be mounted up to 25

 

 

feet from the generator either inside or outside the

 

 

steam room, also see #6 optional secondary digital

 

 

generator control. String the 25' cable from the

6" MIN -

TEMPERATURE

control location through 1/2" holes in the wall studs

 

SENSOR

or ceiling joists to the generator. Note: Do not staple

 

STEAM

through or damage cable. Use factory supplied

 

CONTROL

cables only. Optional for tile rooms, a 1 gang rough-

 

TEMPERATURE

in box may be installed at the desired control

7'

SENSOR

MAX

mounting location. A mounting plate with proper 2"

CABLE

 

CONTROL

diameter hole is included with the control kit. Tile up

 

 

CABLE

to the 2" hole in the mounting plate.

 

 

 

2. Temperature Sensor Rough-in

 

 

It is recommended that the sensor be mounted in

 

 

the steam room 6" from the ceiling, but not directly

 

 

over the steam dispersion head or more than 7 feet

 

 

above the floor. String the sensor cable from the

 

 

sensor location through 1/2" holes in the wall studs

 

 

or ceiling joists to the generator location. Leave 12"

 

 

 

 

of slack at the sensor location. Note: Do not staple through or damage cable. Use factory supplied cables only.

3. Electrical Rough-in

Size wire for the generator as indicated by the Electrical Information Chart on page 4. Use correct size and type to meet electrical codes. Leave 4 feet of slack wire at generator location for finish hookup. Connect the generator to a dedicated circuit breaker. A GFI device is not required by UL. One may be installed if required by local codes or the owner. A GFI device will tend to nuisance trip due to heater element aging.

4. Electrical finish

Materials (locally available):

-3/4" Strain relief for supply wire.

A.Route the copper supply wire with appropriate strain relief through the hole marked POWER ENTRY.

B.Connect the supply wires to the terminal block marked L1 and L2.

C.Connect the ground to the ground lug.

MOUNTING

 

BRACKET

 

CONTROL

WALL

HOUSING

 

 

DECORATIVE

 

CONTROL COVER

 

PLATE

 

 

CONTROL

 

 

HOUSING

2" DIAMETER

 

 

HOLE IN FINISHED

 

CONTROL

WALL

 

 

HOUSING

 

 

CONTROL HOUSING

 

SEALANT

MOUNTING SCREWS

DECORATIVE CONTROL

(MUST FILL GROUT

(DO NOT OVER

COVER PLATE

LINE FOR TILE

TIGHTEN)

 

WALLS).

11

Page 13
Image 13
Jacuzzi SteamPro General Instructions For Temperature Control Models, Control Cable Rough-in, Temperature Sensor Rough-in