Jacuzzi SteamPro A. STEAM CONTROL BY 30 MINUTE LOW VOLTAGE ON/OFF CONTROL, Control cable rough-in

Models: SteamPro

1 22
Download 22 pages 48.97 Kb
Page 12
Image 12
A. STEAM CONTROL BY 30 MINUTE LOW VOLTAGE ON/OFF CONTROL.

INSTALLATION

A. STEAM CONTROL BY 30 MINUTE LOW VOLTAGE ON/OFF CONTROL.

1. Control cable rough-in:

The low voltage control can be mounted up to 75 feet from the generator either inside or outside the steam room. (A 25’ cable provided.) Also, see # 4 Optional Secondary Generator Control. String (3) 18 to 22 AWG solid wires from the control location through 1/2" holes in the wall studes or ceiling joists to the generator.

Note: 1) Do not staple through or damage wires,

2)Label or color code wires for proper TB1 to R30i orientation. See diagram.

2.Control cable at the generator

Route control wires through the generator CONTROL WIRING ENTRY and appropriate strain relief. Connect 3 wires to terminal block TB-1 on the printed circuit assembly, as shown in diagram.

3. Install generator control (R30i)

The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. Using a 1-3/4" hole saw, drill a hole in the finished wall where the control is to be mounted (the control wires should already be roughed-in to this location). Locate the control wires, pull them out through the 1-3/4" hole and plug the 3 wires into the connector on the back of the control housing, as shown in diagram. Run a bead of 100% silicone caulk around the perimeter on the back of the control housing. See diagram. Insert the control into the wall cavity.

4. Optional second generator control

As an option, a second R30i control can be installed with the generator to provide ON/OFF control both inside and outside the steam room. The second control should be installed as described in paragraphs 1 & 3, with the second control wire plugged into the same connector TB1 connector as the first control on the PCA.

THIS LOW VOLTAGE CONTROL CAN

BE LOCATED INSIDE OR OUTSIDE

THE STEAM ENCLOSURE

(OPTIONAL NUT INSTALLATION IF BACK OF WALL IS ACCESSABLE)

APPLY SEALANT

(100% SILICONE CAULK)

1-3/4" DIAMETER HOLE IN FINISHED WALL

BUSHING B

To prepare steam generator:

1.Make certain that power is disconnected. Remove cover.

2.Remove and discard plug from hole A.

3.Feed wire through hole A and connect to TB1 on the circuit board.

4.Locate strain relief bushing 1" from stripped end of cable jacket with the two connectors. Snap strain relief bushing B into hole A.

5.Replace cover.

(3) GREEN

(2) RED

(1) WHITE

HOLE A 1. Control cable rough-in:

TB1

SK1

SK3

SK4

GREEN (3)

RED (2)

WHITE (1)

LOW VOLTAGE CONTROL WIRE (25') IS PROVIDED FOR 5 VOLT DC SWITCH CONNECTION TO STEAM GENERATOR. NO ADDITONAL ELECTRICAL SUPPLY OR WIRING REQUIRED.

10

Page 12
Image 12