INSTALLATION
A. STEAM CONTROL BY 30 MINUTE LOW VOLTAGE ON/OFF CONTROL.
1. Control cable rough-in:
The low voltage control can be mounted up to 75 feet from the generator either inside or outside the steam room. (A 25’ cable provided.) Also, see # 4 Optional Secondary Generator Control. String (3) 18 to 22 AWG solid wires from the control location through 1/2" holes in the wall studes or ceiling joists to the generator.
Note: 1) Do not staple through or damage wires,
2)Label or color code wires for proper TB1 to R30i orientation. See diagram.
2.Control cable at the generator
Route control wires through the generator CONTROL WIRING ENTRY and appropriate strain relief. Connect 3 wires to terminal block
3. Install generator control (R30i)
The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. Using a
4. Optional second generator control
As an option, a second R30i control can be installed with the generator to provide ON/OFF control both inside and outside the steam room. The second control should be installed as described in paragraphs 1 & 3, with the second control wire plugged into the same connector TB1 connector as the first control on the PCA.
THIS LOW VOLTAGE CONTROL CAN
BE LOCATED INSIDE OR OUTSIDE
THE STEAM ENCLOSURE
(OPTIONAL NUT INSTALLATION IF BACK OF WALL IS ACCESSABLE)
APPLY SEALANT
(100% SILICONE CAULK)
BUSHING B
To prepare steam generator:
1.Make certain that power is disconnected. Remove cover.
2.Remove and discard plug from hole A.
3.Feed wire through hole A and connect to TB1 on the circuit board.
4.Locate strain relief bushing 1" from stripped end of cable jacket with the two connectors. Snap strain relief bushing B into hole A.
5.Replace cover.
(3) GREEN
(2) RED
(1) WHITE
HOLE A
TB1
SK1
SK3
SK4
GREEN (3)
RED (2)
WHITE (1)
LOW VOLTAGE CONTROL WIRE (25') IS PROVIDED FOR 5 VOLT DC SWITCH CONNECTION TO STEAM GENERATOR. NO ADDITONAL ELECTRICAL SUPPLY OR WIRING REQUIRED.