Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power and gas to range before servicing, unless testing requires power and/or gas.

Troubleshooting Chart

Problem

Possible Cause

Correction

 

Poor ground on burner cap

Clean burner cap.

Burners will not ignite; no

Weak or failed spark module

Replace spark module.

Low gas pressure

Verify pressure 4" WCP for natural, 10"

spark at top burner.

.

WCP for LP.

 

Clogged burner port

 

Clean burner cap.

 

No 120 VAC to range

Verify voltage at wall outlet.

 

Micro switch contacts not closing

Check wiring against appropriate wiring

 

 

diagram. Verify all terminals and

 

Faulty wiring. Bad connection at

connections are correct and tight.

Burner will not ignite. No

Check micro switch contacts.

burner electrode and electrode socket ..

Check wiring against appropriate wiring

spark to burner ignitors

 

diagram. Verify all terminals and

when burner knob is rotated

 

.

connections are correct and tight.

to "LITE" position.

Inoperative spark module

Check module according to testing

 

 

Electrode dirty. Burner cap dirty

procedures information.

 

Clean electrode or burner cap.

 

Cracked or broken electrode,

 

 

 

electrode wire or electrode socket

Replace electrode.

 

 

 

 

Check for cracked ignitor/pinched wire..

Replace ignitor lead or electrode.

 

Poor continuity to burner cap

Clean burner cap and lead.

No spark or only random

Bad ground connection or lack of

 

continuity to ground or ignitor

Tighten ground connection and correct

spark at one ignitor.

 

any breaks in ground path from ignitor

 

Cracked or broken ignitor extension

 

path to unit ground path.

 

lead

Replace ignitor lead.

 

 

 

 

Shorted valve switch/harness

Replace switch/harness. If shorting is

Unit continues to spark after

 

caused by excessive spillovers,

.

customer education is advised.

knob is turned to OFF

Switch has slipped off the valve

Carefully reposition switch on valve and

position.

 

rotate from OFF to high, several times

 

 

 

 

to verify switch is not broken.

 

No voltage to control

Check for 120 VAC at control. If no

No oven operation in bake or

No voltage from control

voltage check power source.

Check 120 VAC to ignitor, if no voltage,

broil.

Loose wire connection or broken wire ...

replace control.

 

Verify all connections are clean and

 

 

tight, replace broken wire.

No gas flows to burner.

Failed ignitor

Check ignitor current draw, 3.2 – 3.6

Ignitor glows red.

Gas pressure too high

Amps. Replace ignitor if it fails test.

 

Check for correct gas pressure. Natural

 

 

gas pressure should be 5" WCP and LP

 

Failed gas valve

gas pressure should be 10" WCP.

 

Check gas valve for continuity.

 

Loose wire connection or broken wire ...

Verify all connections are clean and

 

 

tight, replace broken wire.