W A R N I N G
DISCONNECT ELECTRICAL SUPPLY BEFORE SERVICING THE APPLIANCE.

Installation Instructions

CONNECTING THE RANGE (cont)

Gas Supply

Installation of this range must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1- latest edition. In Canada the range must be installed in accordance with the current CGA Standard CAN/CGA-B149 - Installation Codes for Gas Burning Appliances and Equipment and/or local codes.

In The Commonwealth Of Massachusetts

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. A “T” handle type manual gas valve must be installed in the gas supply line to this appliance. A flexible gas connector, when used, must not exceed a length of three (3) feet / 36 inches.

W A R N I N G

Gas leaks may occur in your system and result in a dangerous situation. Gas leaks may not be detected by smell alone. Gas suppliers recommend you purchase and install an UL approved gas detector. Install and use in accordance with manufacturer’s instructions.

GAS SUPPLY CONNECTION

A QUALIFIED SERVICEMAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer according to the instructions given in Step 7.

Apply a non-corrosive leak detection fluid to all joints and fittings in the gas connection between the supply line shut-off valve and the range. Include gas fittings and joints in the range if connections were disturbed during installation. Check for leaks! Bubbles appearing around fittings and connections will indicate a leak. If a leak appears, turn off supply line gas shut-off valve, tighten connections, turn on the supply line gas shut off valve, and retest for leaks.

CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME. WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.

NATURAL GAS SUPPLY LINE MUST HAVE A NATURAL GAS SERVICE REGULATOR. INLET PRESSURE TO THIS APPLIANCE SHOULD BE REDUCED TO A MAXIMUM OF 14 INCHES WATER COLUMN (0.5 POUNDS PER SQUARE INCH (P.S.I.) LIQUEFIED PETROLEUM (L.P.)/PROPANE GAS SUPPLY LINE MUST HAVE A L.P. GAS PRESSURE REGULATOR. INLET PRESSURE TO THIS APPLIANCE SHOULD BE REDUCED TO A MAXIMUM OF 14 INCHES WATER COLUMN (0.5 P.S.I.). INLET PRESSURES IN EXCESS OF 0.5 P.S.I. CAN DAMAGE THE APPLIANCE PRESSURE REGULATOR AND OTHER GAS COMPONENTS IN THIS APPLIANCE AND CAN RESULT IN A GAS LEAK.

Gas supply pressure for testing regulator must be at least 1” water column pressure above manifold pressure shown on serial plate.

Check Pressure of House Piping System

1.The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 lbs./sq. in. (3.5 kPa) (13.8 in. water column).

2.The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 lbs./sq. in. (3.5 kPa)

(13.8 in. water column).

A GAS SHUT-OFF VALVE SHOULD BE PUT IN AN ACCESSIBLE LOCATION IN THE SUPPLY LINE AHEAD OF THE RANGE, FOR TURNING ON AND TURNING OFF GAS SUPPLY. CONNECTOR NUTS MUST NOT BE CONNECTED DIRECTLY TO PIPE THREADS. THE CONNECTORS MUST BE INSTALLED WITH ADAPTORS PROVIDED WITH THE CONNECTOR.

The house piping and/or range connector used to connect the range to the main gas supply must be clean, free of metal shavings, rust, dirt and liquids (oil or water). Dirt, etc. in the supply lines can work its way into the range manifold and in turn cause failure of the gas valves or controls and clog burners and/or pilot orifices.

NOTE: It is recommended to use a new CSA certified 1/2” flexible connector no longer than 36” (91.4 cm) with a minimum BTU/HR rating of 60,000 be used. Rigid pipe may also be used.

HOW TO REMOVE RANGE FOR SERVICING

Follow these procedures to remove appliance for servicing:

1. Slide range forward to disengage range from the anti-tip bracket.

2. Shut off gas supply to appliance.

3. Disconnect electrical supply to appliance, if equipped.

4. Disconnect gas supply tubing to appliance.

5. Reverse procedure to reinstall. If gas line has been disconnected, check for gas leaks after reconnection.

6. To prevent range from accidentally tipping, range must be secured to the floor by sliding rear leveling leg into the anti-tip bracket.

NOTE: A qualified servicer should disconnect and reconnect the gas supply. The servicer MUST follow installation instructions provided with the gas appliance connector and the warning label attached to the connector.

SERVICE-PARTS INFORMATION

When your range requires service or replacement parts, contact your dealer or authorized service agency. Please give the complete model and serial number of the range which is located on front frame behind storage drawer.

Your range may not be equipped with some of the features referred to in this manual.

A – 4

16026923

© 2006 Maytag Services

Page 34
Image 34
Jenn-Air JGS8750BD, JGS9900BD, JGS8860BD, JGS8850BD manual Gas Supply, Check Pressure of House Piping System

JGS9900BD, JGS8860BD, JGS8850BD, JGS8750BD specifications

The Jenn-Air JGS8750BD, JGS8850BD, JGS8860BD, and JGS9900BD are a series of high-performance gas cooktops designed for culinary enthusiasts who value precision and sophistication. These models are distinguished by their robust construction, modern aesthetics, and a range of innovative features that streamline the cooking process.

One of the key features across these models is the professional-grade burners. The JGS8750BD, for instance, boasts a powerful 20,000 BTU burner, perfect for high-heat searing and rapid boiling. In contrast, the JGS8850BD offers a versatile 15,000 BTU burner, catering to a variety of cooking needs, including simmering and sautéing. For more delicate tasks, the JGS8860BD showcases a 5,000 BTU burner designed for simmering sauces and cooking delicate dishes with precision.

Another notable characteristic of these cooktops is the incorporation of the Jenn-Air® Turbo Flame™ technology. This feature provides an exceptional level of control, allowing chefs to achieve the desired temperature with accuracy. This technology is particularly valuable for those who require consistent heat for intricate recipes and techniques.

The seamless stainless-steel design not only elevates the appearance of any kitchen but also offers easy cleaning and maintenance. The high-quality grates found on these models are designed for durability and stability, ensuring pots and pans remain securely in place during cooking. Additionally, the continuous surface grates facilitate effortless sliding of cookware from one burner to another.

The JGS9900BD stands out with its advanced electronic ignition system, which ensures that the burners ignite quickly and reliably, minimizing downtime in the kitchen. Safety is also a priority across these models, featuring flame failure detection that automatically shuts off the gas supply if a flame goes out.

In terms of size, these cooktops cater to different kitchen configurations, with varying configurations to suit individual preferences and space constraints. Whether you're an avid home cook or a professional chef, the Jenn-Air JGS8750BD, JGS8850BD, JGS8860BD, and JGS9900BD combine superior technology with elegant design, making them a valuable addition to any modern kitchen. This series exemplifies Jenn-Air's commitment to quality, performance, and aesthetics, ensuring an elevated cooking experience for all users.