Jenn-Air Refrigerator General Use Conditions, System Specification and Performance Data Sheet

Models: Refrigerator

1 33
Download 33 pages 30.44 Kb
Page 18
Image 18
System Specification and Performance Data Sheet

System Specification and Performance Data Sheet

Refrigerator Water FHter Cartridge Mode U KF8001A××

Specifications

Service

Flow

Rate (Maximum]

0 78 GPM

(2.9 L/mini

Rated

Service

Life UKF8001AXX-750 (Maximum]

750 gallons!2838 liters

Maximum

Operating

Temperature

100° F/38 ° C

Minimum

Pressure

Requirement

35 psi!241

kPA

Minimum

Operating

Temperature

33° F/1 ° C

 

Maximum

Operating

Pressure

120 psi/827

kPA

Performance Data

Standard No. 42: Aesthetic Effects

1000 Apollo Road

Eagan, Minnesota 55121-2240

651.450.4913 EPA EST #35917-MN-1

100834/B

 

 

 

 

 

USEPA

Influent

Influent

 

 

Effluent

 

 

%

Reduction

Min. Required

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

MCL

Challenge

Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Clllorine

 

 

 

 

 

2.0 mg/L

_+10%

1.88 mg/L

<0.05136364

mg/[

0.06

mg/L

>9726o/o

96.84o/o

50%

T&O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Particulate**

 

 

 

 

at least 10,000

particles/ml

5,700.000

#/ml

30,583

 

#/ml

69,000

 

#/ml

99.52o/o

98.94o/o

85%

 

 

 

 

 

 

 

Standard No. 53: Health Effects

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USEPA

Influent

Influent

 

 

Effluent

 

 

%

Reduction

Mini Required

 

 

 

 

 

MCL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

 

Challenge

Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Turbidity

 

 

 

1 NTU _*

11 ±

1 NTU***

10.7

NTU

0.31 NTU

.049 NTU

97.09%

95.20%

0.5 NTU

Cysts

 

 

 

 

99.5% Reduction

Minimum

5O,000/L

166,500

#/L

<1

#/L

<1

#/L

>99.99%

>99.99%

>99.95%

Asbestos

 

 

 

99% Reduction

107108fibers/L; fibers >10 micrometers in length

155

MF/L

<1

MF/L

<1 MF/L

>99.99%

>99.99%

99%

Lead

at pH

6.5

 

0.015

mg/L

0.15 mg/L

+ 1O%

0.153

mg/L

<.001

 

mg/L

<.001

 

mg/L

>99.35%

>9929%

0.10 mg/L

Lead

at pH

8.5

 

0.015

mg/L

0.15 mg/L

+ 1O%

0.150

mg/L

<.001

 

mg/L

<.001

 

mg/L

>99.33%

>99.29%

0.19 mg/L

MercLny

at pH

6.5

0.002

mg/L

.006 mg/L

_+1O%

0.006

mg/L

0.0003 mg/L

0.0005 mg/L

95.70%

90.91%

0.992 mg/L

MercLny

at pH

8.5

0.002

mg/L

.006 mg/L

_+1O%

0.006

mg/L

0.0008 mg/L

0.0015 mg/L

86.22%

75.93%

0.992 mg/L

Atrazine

 

 

 

0.003

mq/L

0.009 m g/L

+ 10%

0.009

m q/L

<0.002

mg/L

0.002 mg/L

76,99%

75.31%

0.993 m g/L

Benzene

 

 

 

0.005

mg/L

0.015 m g/L

_+10%

0.014

m_/L

0.0006 mg/L

0.0011 m_)/L

95.71o/o

92.14o/o

0.995 mg/L

Carbofuran

 

 

 

0.04 m_)/L

0.08 m{)/L

_+10%

0.081

m_)/L

<0.001

mg/L

<0.001

 

m_)/L

98.74o/o

98.46%

0.04 m_)/L

>Dichlolobenzene

 

0.075

mg/L

.225 m q/L

_+1O%

0.208

m_/L

<0.0005

mq/L

<0.0005

m_/L

99.76o/o

99.74o/o

0.075 m q/L

Lindane

 

 

 

0.0002 mf_/L

0.002 mf_/L + 10%

0.002

m g/L

0.0OOmf_/L

<0.0001

mq/L

98.72o/o

96.50o/o

0.0092 mg/L

Toxaphene

 

 

 

0.003

mg/L

0.015

±

10%

0.015

mg/L

<0.001

mg/L

<0.001

 

mg/L

92.970/o

91.67%

0.993 mg/L

Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 75 + 0.5; temp. of 68 ° + 5° F (20 ° + 3° C)

** Measurement in Particles/ml. Particles used were 0.5 - 1 microns

*** NTU - Nephelometric Turbidity Units

Tested and certified by NSF International against ANSI/NSF Standards 42 & 53

in models UKF8001AXX-750 for the reduction of:

Standard

No.

42:

Aesthetic

Effects

Standard

No. 53:

Health

Effects

Taste and

Odor

Reduction

 

Cllenlical

Reduction

Unit

 

 

Clllorine

Taste

& Odor

 

Lead. Atrazine,

Lindane,

Benzene,

Mechanical

Filtration

Unit

 

Carbofuran,

 

p-Dichlorobenzene,

Mercury

Particulate

Reduction

Class

1

& Toxaphene

Reduction

 

 

 

 

 

 

 

Mechanical

 

Filtration

Unit

 

 

 

 

 

 

 

Cyst, Turbidity and Asbestos

Reduction

General Use Conditions

Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs.

DO NOT use this product where water is microbiologic- ally unsafe or of unknown quality without adequate disinfection before or after the system. System certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

USE ONLY WITH COLD WATER SUPPLY. CHECK FOR COMPLIANCE WITH THE STATEAND LOCAL LAWS AND REGULATIONS.

The PuriClean" II retractable water filtration system uses a UKF8001AXX replacement cartridge. Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system. Please refer to the applicable section of your Use & Care Guide for general operation, maintenance requirements and troubleshooting. Suggested retail price of replacement water filter is $39.99.

This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substance listed above. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.

17

Page 18
Image 18
Jenn-Air Refrigerator General Use Conditions, System Specification and Performance Data Sheet, Specifications