5.Slide-In Cutout (Figure5)

5.Slide-In Cutout (Figure5)

*Use the overhang measurementto figure the "A" dimension:

Overhang 1/2" (1.27 cm) to 1" (2.54 cm) .... "A" = 22-5/8"(57,47cm)

Overhang 1" (2.54 cm) to 1-3/4"(4.45 cm) .... "A" = 23" (55.42cm)

. Carefullymarkthe countertopand recheckyour dimensions.

Before you cut, checkthe rear countertopdimensions. (See#6.)

NOTE:The minimumclearancebetweenthe cutoutand cabinetdoors and drawer edge is 7/8".

6. Slide-In Cutout (Figure 6)

Check your marked up dimensionscarefully.The rear dimensions shown in the illustrationmust be maintained.

NOTE:Wherethis isnot done,it willbe necessaryto relievea portionof the undersideof the countertop and/or support members to clear the range rear panel.

Cutting tolerance is = 1/'6(.16 cm.)

Carefullymake the cutout.

7. Free-StandingCutout (Figure 7)

30-1/'8"(76.52cm) minimumclearance is required.

Carefully mark the countertop, recheck your dimensions and make the cutout.

NOTE:Range side panels may be desirable if the cutout is too large or

Proceedto step 8.

_, Over-RangeCabinets (Figure 8)

-To eliminate the hazard of reaching over a heated surface unit, cabinet storage space abovethe rangeshould be avoided. If cabinet storageis to be provided,the riskcanbe reducedby installinga rangehoodthat projects horizontallya minimum of 5 inches beyond the bottom of the cabinets.

However,if over-rangecabinetsare necessary,observethe following: cabinetsare on one side of the range only.

B = 30" (76.2cm) minimum clearance betweenthe top of the cooking platformand the bottom of an unprotectedwood or metal cabinet.

protected by not less than 1/4" (0.635 cm) FLAME RETARDANT B = 24" (60,96 ore) minimumwhen bottomof wood or metal cabinet is millboardcovered with not less than No. 28MSGsheet steel, 0.015"

(0.038 cm) stainless steel,0.024" (0.061 cm) aluminumor copper. NOTE:If you are NOT installinga downdraftunit, skip to step 13.

9.Measure For Floor Vent

If unit will be ventedthrough the wall, go to #11.

If floor willbe concrete slab,see enclosedductinginstructions.

For let and right hand venting through cabinet toe space, see special instructionson pages 7 & 8.

NOTE:Optimumcenterlinevent locationis 11"to 17" fromedgeof cabinet. Ventslocatedless thanthis distancewill requiretheunitto be raised over blower for installation.

_" FloorVent Cutout(Figure 10)

-Checkthe direction of the floor joists (seeillustration.)

Locate6" square cutout anywherewithin shadedarea. The cutout must miss the floor joists!

Recheckyour dimensions and make the cutout.

Skip to Step #12.

(Figure5)

(Figure 6)

3or.- .1/le,,

_-"'T_'[

1./,._,.-

 

(Figure 7)

 

 

_J_______._-_.

_

_)

 

_

 

 

 

)"

_ ""

I

_--

_

 

T

 

IF

//_/_

 

/

 

 

_

O O

O O

 

(Figure8)

(Figure 10)

3

Page 3
Image 3
Jenn-Air SVE47100 Slide-InCutout Figure, Free-StandingCutout Figure, Over-RangeCabinetsFigure, Measure For Floor Vent