Jenn-Air LI3URB/W10274314C Connect Vent System, For vented installations only

Models: LI3URB/W10274314C W10274314C

1 32
Download 32 pages 50.63 Kb
Page 10
Image 10
Connect Vent System

Connect Vent System

This range hood is factory set for 8" (20.3 cm) round venting through the roof or wall. An 8" (20.3 cm) round vent system is needed for installation (not included). To vent through the wall, a 90° elbow is needed.

This range hood can also be set for rear venting using the

3¼" x 10" (8.3 x 25.4 cm) rectangular damper (supplied). See the “Connect Vent System - For Rear Venting Installation Only” section.

For vented installations only:

1.Fit vent system over transition piece.

2.Seal connection with clamps.

3.Check that backdraft dampers work properly.

For non-vented (recirculating) installation with vent cover only:

1.Assemble the air deflector with the duct cover bracket with 4 - assembly screws provided with the Recirculation Kit.

A

B

C

A. Assembly screws

B. Air deflector

C. Duct cover bracket

2.Measure from the bottom of the air deflector to the bottom of the hood exhaust outlet.

 

A

B

 

X

C

D

 

E

 

A. Air deflector

B. Vent clamp

C. X = length to cut vent duct

D. 8" (20.3 cm) dia. round vent duct

E. Hood exhaust outlet

3.Cut the duct to the measured size (X).

4.Remove the air deflector.

5.Slide the duct onto the bottom of the air deflector.

6.Place the assembled air deflector and duct over the exhaust outlet from the hood.

7.Reassemble the air deflector to the duct cover bracket with 4 assembly screws.

8.Seal connections with vent clamps.

For non-vented (recirculating) installation without vent cover only:

1.Push in the bottom of the center glass to unlatch, and lift to open.

2.Remove metal filter. See the “Range Hood Care” section.

3.Remove the 4 mounting screws holding the 8" (20.3 cm) diameter transition damper to the canopy top. Set the damper and mounting screws aside.

A

A. Damper mounting screws

4.Install the top grille cap using the mounting screws included in the Recirculation Kit.

10

Page 10
Image 10
Jenn-Air LI3URB/W10274314C installation instructions Connect Vent System, For vented installations only