Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
4.Run home power supply cable through strain relief into the terminal box.
A BC
D
F
1. Disconnect power. | E |
|
2.Remove the 5 screws from the top cover of the range hood to uncover the terminal box.
A
A
B
A
A. Cover screws
A. Top cover
3.Remove terminal box cover and the knockout. Install a UL listed or CSA approved ½" strain relief.
A
B
A.Knockout
B.Terminal box cover
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F.Green (or bare) and
5.Use UL listed wire connectors and connect black wires (C) together.
6.Use UL listed wire connectors and connect white wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
7.Connect green (or bare) ground wire from home power supply to
8.Tighten strain relief screw.
9.Install terminal box cover.
10.Check that all light bulbs are secure in their sockets.
11.Reinstall top cover using 5 screws removed previously. Tighten screws.
12.Reconnect power.
11