Using LANVIEW

Table 4-1 LANVIEW LEDs

 

 

 

 

 

LED

Color

State

Recommended Action

 

 

 

 

CPU

Off

Power off.

Ensure chassis has adequate power.

 

 

 

 

 

Red

Blinking. Hardware

Contact Enterasys Networks for technical

 

 

failure has occurred.

support.

 

 

 

 

 

 

Solid. Resetting, normal

If the LED remains red for several minutes,

 

 

power up reset.

contact Enterasys Networks for technical

 

 

 

support.

 

 

 

 

 

Amber

Blinking. Crippled.

Contact Enterasys Networks for technical

 

 

 

support.

 

 

 

 

 

 

Solid. Testing.

If the LED remains amber for more than

 

 

 

several minutes, contact Enterasys

 

 

 

Networks for technical support.

 

 

 

 

 

Green

Solid. Functional.

None.

 

 

 

 

 

Amber

Booting. Blinks amber

None.

 

and

and green while booting.

 

 

Green

 

 

 

 

 

 

RX

Off

No link.

None.

(Receive)

 

No activity or port in

 

 

 

standby. Port enabled or

 

 

 

disabled.

 

 

 

 

 

 

Green

Solid. Link, port enabled,

None.

 

 

no activity.

 

 

 

 

 

 

 

Blinking. Link, port

None.

 

 

disabled.

 

 

 

 

 

 

Amber

Flashing. Link, port

None.

 

 

enabled, activity.

 

 

 

 

 

 

Red

Solid. Diagnostic failure.

Contact Enterasys Networks for

 

 

 

assistance.

 

 

 

 

Troubleshooting 4-3

Page 41
Image 41
Enterasys Networks 6H302-48 manual Led