Jenn-Air LI3ZVB/W10342490D Install Vent System, Example Vent System, 3¹⁄₄ x 10 8.3 cm x 25.4 cm

Models: LI3ZVB/W10342490D W10342490D

1 36
Download 36 pages 34.74 Kb
Page 9
Image 9
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
= 10.0 ft (3 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m)
= 4.5 ft (1.4 cm)
= 22.5 ft (6.8 m)

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

Vent Piece

Rectangular

 

 

 

 

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

90° elbow

(1.5 m)

 

 

 

 

 

 

 

 

 

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

12.0 ft

flat elbow

(3.7 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

0.0 ft

wall cap

(0.0 m)

 

 

 

 

 

 

 

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

 

 

 

 

 

 

 

90° elbow

5.0 ft

 

(1.5 m)

 

 

 

 

 

 

 

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

 

 

 

 

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

 

 

 

 

 

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

 

 

 

 

 

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

transition

 

 

 

 

 

 

 

 

 

 

 

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

 

 

 

 

 

 

 

 

 

 

 

 

Example Vent System

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 ft

 

A

 

B

 

 

 

 

 

 

 

(1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft (0.6 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

A. Blower motor

C. 90° elbows

 

B. Transition

D. Back draft damper

The following example falls within the maximum vent length of 35 ft (8.9 m).

2 - 90° elbow

1 - wall cap

8 ft (2.4 m) straight Transition

Length of 6" (15.2 cm) or 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) system

Install Vent System

WARNING

Excessive Weight Hazard

Use two or more people to move and install downdraft vent.

Failure to do so can result in back or other injury.

1.Place cardboard or similar material on top of a flat surface where you can easily assemble the downdraft vent system.

2.Remove parts packages, downdraft vent and blower box from the carton.

3.Remove all shipping materials, tape and film from the downdraft vent and blower box.

4.Install the right and left undercounter mounting brackets to the vent box. Slide the keyhole slots over the guide tabs and push the brackets up to set them into place.

B

AVent PieceRectangular

6" (15.2 cm) RoundExample Vent SystemInstall Vent SystemExcessive Weight HazardUse two or more people to move and install downdraft vent.Failure to do so can result in back or other injury.Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundC

D

A. Vent box

B. Undercounter mounting bracket

C. Keyhole slots

D. Guide tabs

9

Page 9
Image 9
Jenn-Air LI3ZVB/W10342490D Install Vent System, Example Vent System, 3¹⁄₄ x 10 8.3 cm x 25.4 cm, Vent Piece, Rectangular