Jenn-Air W10430955A Bare Wire Torque Specifications, wireconnection Direct Wire, A B C D E, G A B

Models: W10430955A

1 40
Download 40 pages 32.16 Kb
Page 18
Image 18
A

3.Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach wiring to the terminal block.

A

B

 

C

G

D

 

F

E

 

A. Terminal block

E. Neutral (white) wire

B. Ground-link screw

F. Line 1 (black) wire

C. Cord/conduit plate

G. Bare (green) ground wire

D. Line 2 (red) wire

 

4.Attach terminal lugs to line 1 (black), neutral (white), and line 2 (red) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten set screw to torque as shown in the following Bare Wire Torque Specifications chart.

A

Bare Wire Torque SpecificationsWire AwgB

C D E

A. Terminal lug

D. Neutral (white) wire

B. Setscrew

E. Line 2 (red) wire

C. Line 1 (black) wire

 

Bare Wire Torque Specifications

Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)

Wire Awg

Torque

8 gauge copper

25 lbs-in. (2.8 N-m)

 

 

6 gauge aluminum

35 lbs-in. (4.0 N-m)

 

 

5.Use Phillips screwdriver to connect the bare (green) ground wire to the range with the ground-link screw. The ground wire must be attached first and must not contact any other terminal.

6.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

G

A TorqueG

B

 

 

F

 

D

E

C

 

 

 

A. 10–32 hex nut

E. Neutral (white) wire

B. Line 1 (black)

F. Line 2 (red)

C. Bare (green) ground wire

G. Terminal lug

D.Ground-link screw

7.Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with 10-32 hex nuts.

8.Securely tighten hex nuts.

9.Replace terminal block access cover.

3-wire connection: Direct Wire

Use this method only if local codes permit connecting ground conductor to neutral supply wire.

1.Pull the conduit through the hole and conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A 3-wire connection: Direct WireManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

B

 

 

C

 

 

D

F

E

 

 

 

A. Terminal block

D. Line 2

(red) wire

B. Ground-link screw

E. Bare (green) ground wire

C. Cord/conduit plate

F. Line 1

(black) wire

18

Page 18
Image 18
Jenn-Air W10430955A Bare Wire Torque Specifications, wireconnection Direct Wire, A B C D E, G A B, Wire Awg