4.Remove 4 locknuts on the motor side of the blower and remove the bracket.
View from Motor Side of Blower
A
A. Electrical connector
5.Lift and rotate the motor 180° to reposition the electrical connection.
A
A. Electrical connector
6.Rotate bracket 180° and secure with 4 locknuts.
8.Position 2 wood spacers and mount them to the floor.
Top View
| B |
| C |
A | D D |
|
A. 2" x 4" (5.0 x 10.2 cm) wood spacers
B. 2⁷⁄₉" (7.3 cm) from back wall to edge of wood spacer C. 8¾" (22.2 cm)
D. 2⁵⁄₁₆" (5.8 cm) centerline of opening to wood spacer
9.Mount blower motor to wood spacers using 4 - #8 x ¾" hex head screws provided.
NOTE: Vent system will be connected after range has been moved into it’s final location. “See Connect Range to Downdraft System” section.
Top View
B |
C |
A |
7.Remove the bracket from the other side of the blower motor, rotate 180° and secure with 4 locknuts.
A. Wood spacers
B. Mounting bracket
C. Blower
10. Go to the “Electrical Connection” section.
13