Jenn-Air W10430955A Electrical Connection - U.S.A. Only, Power Supply Cord, Direct Wire

Models: W10430955A

1 40
Download 40 pages 32.16 Kb
Page 14
Image 14
Electrical Connection - U.S.A. Only

Electrical Connection - U.S.A. Only

Power Supply Cord

 

Direct Wire

Power Supply CordWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

Direct WireWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

1.Disconnect power.

2.Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range. Pull cover down and toward you to remove cover.

Style 1: Power supply cord strain relief

Assemble a UL listed strain relief in the opening.

3.Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.

A

A. UL listed strain relief

Feed the power supply cord through the opening in the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

Tighten strain relief screw against the power supply cord.

4.Add strain relief.