Johnson Controls TM9X*MP installation manual Installation Manual, Residential Gas Furnace, Safety

Models: TM9X*MP

1 38
Download 38 pages 44.62 Kb
Page 1
Image 1
INSTALLATION MANUAL

INSTALLATION MANUAL

RESIDENTIAL GAS FURNACE

MODELS: TM9X*MP – High Efficiency Motor

(95.5% AFUE Single Stage Multi-position)

LIST OF SECTIONS

SAFETY

. 2

COMBUSTION AIR and VENT SYSTEM

21

DUCTWORK

. 5

START-UP AND ADJUSTMENTS

28

FILTERS

. 9

SAFETY CONTROLS

33

GAS PIPING

10

NORMAL OPERATION AND DIAGNOSTICS

34

ELECTRICAL POWER

12

REPLACEMENT PARTS LIST

36

CONDENSATE PIPING AND FURNACE

 

WIRING DIAGRAM

37

VENTING CONFIGURATION

15

 

 

LIST OF FIGURES

Duct Attachment

. 5

Upflow Configuration

17

Vertical Applications

. 6

Downflow Configuration

18

Coil Flange

. 6

Horizontal Left Configuration

19

Horizontal Right Application

. 6

Horizontal Right Configuration

20

Horizontal Left Application

. 6

Dimensions

22

PC Series Upflow Coil Installation

. 7

Home Layout

23

Horizontal Left or Right application (Right Shown)

. 7

Termination Configuration - 1 Pipe

24

Combustible Floor Base Accessory

. 7

Termination Configuration - 2 Pipe

24

Horizontal Application

. 8

Termination Configuration - 2 Pipe Basement

24

Typical Attic Installation

. 8

Double Horizontal Combustion Air Intake and Vent Termination . . .

24

Typical Suspended Furnace / Crawl Space Installation

. 8

Double Vertical Combustion Air Intake and Vent Termination

24

Downflow Venting

. 8

Downward Venting

25

Dimensions

. 9

Direct Vent Air Intake Connection and Vent Connection

25

Side Return Cutout Markings

10

Combustion Airflow Path Through The Furnace Casing

25

Gas Valve

10

Outside and Ambient Combustion Air

27

Gas Piping

10

Attic and Crawl Space Combustion Air Termination

28

Electrical Wiring

12

Gas Valve

31

Thermostat Chart - Single Stage AC with Single Stage Furnaces . .

13

Reading Gas Pressure

31

Thermostat Chart - Single Stage HP with Single Stage Furnaces . .

14

Furnace Control Board

32

Typical. Condensate drain, vertical installation

15

Wiring Diagram

37

Typical. Combustion Pipe Drain Tee

16

 

 

LIST OF TABLES

Unit Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Coil Projection Dimensions - PC Series Coils . . . . . . . . . . . . . . . . . . 7 Cabinet and Duct Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Recommended Filter Sizes (High Velocity 600 FPM) . . . . . . . . . . . . 9 Nominal Manifold Pressure - High Fire . . . . . . . . . . . . . . . . . . . . . . 11 Ratings & Physical / Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . 12 Maximum Equivalent Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Equivalent Length of Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Combustion Air Intake and Vent Connection

Size at Furnace (All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Unconfined Space Minimum Area . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Gas Rate (CU FT/HR) at Full Input . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Blower Performance CFM - Any Position (without filter) . . . . . . . . . . 33

These high efficiency, compact units employ induced combustion, reli- able hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applica- tions.

These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and oper- ation.

These units are Category IV listed and may not be common vented with another gas appliance as allowed by the National Fuel Gas Code.

Johnson Controls Unitary Products

697936-UIM-B-01211

Page 1
Image 1
Johnson Controls TM9X*MP installation manual Installation Manual, Residential Gas Furnace, List Of Sections, Safety