INSTALLATION MANUAL
RESIDENTIAL GAS FURNACE
MODELS: TM9X*MP – High Efficiency Motor
(95.5% AFUE Single Stage Multi-position)
LIST OF SECTIONS
SAFETY | . 2 | COMBUSTION AIR and VENT SYSTEM | 21 |
DUCTWORK | . 5 |
| 28 |
FILTERS | . 9 | SAFETY CONTROLS | 33 |
GAS PIPING | 10 | NORMAL OPERATION AND DIAGNOSTICS | 34 |
ELECTRICAL POWER | 12 | REPLACEMENT PARTS LIST | 36 |
CONDENSATE PIPING AND FURNACE |
| WIRING DIAGRAM | 37 |
VENTING CONFIGURATION | 15 |
|
|
LIST OF FIGURES
Duct Attachment | . 5 | Upflow Configuration | 17 |
Vertical Applications | . 6 | Downflow Configuration | 18 |
Coil Flange | . 6 | Horizontal Left Configuration | 19 |
Horizontal Right Application | . 6 | Horizontal Right Configuration | 20 |
Horizontal Left Application | . 6 | Dimensions | 22 |
PC Series Upflow Coil Installation | . 7 | Home Layout | 23 |
Horizontal Left or Right application (Right Shown) | . 7 | Termination Configuration - 1 Pipe | 24 |
Combustible Floor Base Accessory | . 7 | Termination Configuration - 2 Pipe | 24 |
Horizontal Application | . 8 | Termination Configuration - 2 Pipe Basement | 24 |
Typical Attic Installation | . 8 | Double Horizontal Combustion Air Intake and Vent Termination . . . | 24 |
Typical Suspended Furnace / Crawl Space Installation | . 8 | Double Vertical Combustion Air Intake and Vent Termination | 24 |
Downflow Venting | . 8 | Downward Venting | 25 |
Dimensions | . 9 | Direct Vent Air Intake Connection and Vent Connection | 25 |
Side Return Cutout Markings | 10 | Combustion Airflow Path Through The Furnace Casing | 25 |
Gas Valve | 10 | Outside and Ambient Combustion Air | 27 |
Gas Piping | 10 | Attic and Crawl Space Combustion Air Termination | 28 |
Electrical Wiring | 12 | Gas Valve | 31 |
Thermostat Chart - Single Stage AC with Single Stage Furnaces . . | 13 | Reading Gas Pressure | 31 |
Thermostat Chart - Single Stage HP with Single Stage Furnaces . . | 14 | Furnace Control Board | 32 |
Typical. Condensate drain, vertical installation | 15 | Wiring Diagram | 37 |
Typical. Combustion Pipe Drain Tee | 16 |
|
|
LIST OF TABLES
Unit Clearances to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Coil Projection Dimensions - PC Series Coils . . . . . . . . . . . . . . . . . . 7 Cabinet and Duct Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Recommended Filter Sizes (High Velocity 600 FPM) . . . . . . . . . . . . 9 Nominal Manifold Pressure - High Fire . . . . . . . . . . . . . . . . . . . . . . 11 Ratings & Physical / Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . 12 Maximum Equivalent Pipe Length . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Elbow Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Equivalent Length of Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Combustion Air Intake and Vent Connection
Size at Furnace (All Models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Estimated Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Unconfined Space Minimum Area . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Free Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Gas Rate (CU FT/HR) at Full Input . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Inlet Gas Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Nominal Manifold Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Blower Performance CFM - Any Position (without filter) . . . . . . . . . . 33
These high efficiency, compact units employ induced combustion, reli- able hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applica- tions.
These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and oper- ation.
These units are Category IV listed and may not be common vented with another gas appliance as allowed by the National Fuel Gas Code.
Johnson Controls Unitary Products |