Heat & Glo LifeStyle CERONA-42 Vent Information and Diagrams, Vent Table Key, Use of Elbows

Models: CERONA-42 CERONA-36

1 62
Download 62 pages 22.54 Kb
Page 14
Image 14

5 Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in the vent diagrams.

Symbol

Description

V1

First section (closest to appliance) of vertical length

 

 

V2

Second section of vertical length

 

 

H1

First section (closest to appliance) of horizontal length

 

 

H2

Second section of horizontal length

 

 

WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney flue serving a separate solid-fuel or gas burning appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or other appliances connected to the flue.

B.Use of Elbows

CAUTION

ALL vent configuration specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

Vertical

8-1/2iN.

8-1/2 in.

Horizontal

Figure 5.1

C. Measuring Standards

Vertical and horizontal measurements listed in the vent diagrams were made using the following standards.

1.Pipe measurements are shown using the effective length of pipe (see Figure 5.2).

2.Measurements are made from the appliance outer wrap, not from the standoffs.

3.Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Fig- ure 4.1).

4.Vertical terminations are measured to bottom of termi- nation cap.

5.Horizontal pipe installed level with no rise.

Diagonal runs have both vertical and horizontal vent as- pects when calculating the effects. Use the rise for the ver- tical aspect and the run for the horizontal aspect (see Fig- ure 5.1).

Two 450 elbows may be used in place of one 900 elbow. On 450 runs, one foot of diagonal is equal to 8.5 inches hori- zontal run and 8.5 inches vertical run. A length of straight pipe is allowed between two 450 elbows (see Figure 5.1).

DVP PIPE

Effective

Height/Length

Pipe

Length/Inches

 

 

 

DVP4

4

102

DVP6

6

152

DVP12

12

305

DVP24

24

610

DVP36

36

914

DVP48

48

1219

DVP6A

3 to 6

76 to152

DVP12A

3 to 12

76 to305

DVP12MI

3 to 12

76 to305

DVP24MI

3 to 24

76 to610

Figure 5.2 DVP Pipe Effective Length

14

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06