Heat & Glo LifeStyle CERONA-36, CERONA-42 Electrical Information, Recommendation for Wire

Models: CERONA-42 CERONA-36

1 62
Download 62 pages 22.54 Kb
Page 31
Image 31

10 Electrical Information

A. Recommendation for Wire

This appliance requires 110-120 VAC be wired to the junction box for proper operation of the appliance. This appliance uses an Intellifire ignition system.

NOTE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70- latest edition or the Canadian Electric Code, CSA C221.1.

B. Connecting to the Appliance

C. Intellifire Ignition System Wiring

This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.1.

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system. This appliance is supplied with a battery pack which requires two D cell batteries (not included). Batteries cannot be placed in the battery pack while using the 3 volt AC transformer. Conversely, the transformer must be unplugged if the battery pack is used.

WARNING

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

Incorrect wiring will damage millivolt valves.

Incorrect wiring will override IPI safety lockout and may cause explosion.

This appliance includes the WSK300-HNG wall control. It requires the installation of a wall switch, to be con- nected to this appliance. Please reference the WSK300- HNG instructions (2101-915) for specific installation and operating instructions.

Use the wire provided with this product to connect the wall switch with the receiver control, as outlined in the instructions for the WSK300-HNG control.

Keep wire lengths short as possible by removing any excess wire length.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

CAUTION

Battery polarity must be correct or module damage will occur.

Optional Accessories Requirements

Wiring for optional accessories should be done now to avoid reconstruction.

CAUTION

Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause improper and dangerous op- eration. Verify proper operation after servicing.

WARNING

Shock hazard.

Replace damaged wire with type 105O C rated wire.

Wire must have high temperature insulation.

Heat & Glo • Cerona-36, Cerona-422106-900 Rev. A • 6/06

31

Page 31
Image 31
Heat & Glo LifeStyle CERONA-36 Electrical Information, Recommendation for Wire, Optional Accessories Requirements