Channelized OC12 PIC

Alarms, errors, and events

Alarm indication signal (AIS-L, AIS-P)

BERT functionality (you can configure one DS3 channel in BERT mode and configure the remaining channels to transmit and receive normal traffic)

Bit error rate signal degrade (BERR-SD), Bit error rate signal fail (BERR-SF)

Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)

Equipment failure (Does not affect service)

Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), far-end block error (FEBE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)

Frame error

Idle code, Idle received

Loss of frame (LOF), Loss of pointer (LOP-P), Loss of signal (LOS)

Out of frame (OOF)

Payload Mismatch (PLM-P), Payload Unequipped (UNEQ-P)

Parity bit (P-bit) disagreements

Path parity error

Remote defect indication (RDI-L, RDI-P)

Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)

Yellow alarm bit (X-bit) disagreements

Table 9: Optical Interface Support for Channelized OC12 PICs

Optical Parameter

Single-Mode Intermediate Reach

Optical interface

Single-mode transmitter

Standard

Telcordia GR-253 compliant

Maximum distance

Single-mode cable: 9.3 miles/15 km

Wavelength

1274 through 1356 nm

Average launch power

–15 through –8 dBm

Receiver saturation

–8 dBm

Receiver sensitivity

–28 dBm

Channelized OC12 PIC 29

Page 29
Image 29
Juniper Networks M20 Optical Interface Support for Channelized OC12 PICs, Optical Parameter Single-Mode Intermediate Reach