Parameter Possible settings Description
REMOTE SELECT [OFF]
DV (SLAVE)
DV (TRIGGER)
REMoTE [oFF]
dVS
dVT
REC CONTROL [OFF]
ON
REC [oFF]
oN
FOOT SW1 OFF
[LOW EDGE]
HIGH EDGE
LOW LEVEL
FSW1 oFF
[LE]
HE
LL
FOOT SW2 OFF
[LOW EDGE]
HIGH EDGE
BOTH EDGE
FSW2 oFF
[LE]
HE
bE
232C [9600]
BAUDRATE 19200
Bps [96]
192
This parameter is used to select a method for controlling external devices connected
via the DV IN/OUT terminal).
OFF :Control is not to be carried out via the DV IN/OUT terminal.
This is the standard setting for normal operation.
DV (SLAVE) :This DVD recorder will become the slave device and will be
controlled by the master device.
DV(TRIGGER) :This setting is made when this DVD recorder is connected to a DV
camera featuring a DV record triggering function, and it allows
this DVD recorder to record video from the camera in response to
operation of its trigger button.
This parameter is used to indicate whether or not the REC CONTROL panel is to be
displayed on the monitor screen.
ON :The REC CONTROL panel is to be displayed only when a recordable disc
has been inserted and the DVD recorder is in Stop, Recording, or Recording
Pause mode.
OFF :The REC CONTROL panel not to be displayed.
Set this item when connecting an external switch (foot switch, etc.) to the FOOT
SW1 terminal.
OFF :Set to this when an external switch is not used.
LOW EDGE :Switch between recording and record pause actions using the low
edge of external switch signals.
HIGH EDGE :Switch between recording and record pause actions using the high
edge of external switch signals.
LOW LEVEL :Use the low level and high level of external switch signals for recording
and record pause respectively.
Set this item when connecting an external switch (foot switch, etc.) to the FOOT
SW2 terminal.
OFF :Set to this when an external switch is not used.
LOW EDGE :Add chapter marks and indexes using the low edge of external switch
signals.
HIGH EDGE :Add chapter marks and indexes using the high edge of external switch
signals.
BOTH EDGE:Add chapter marks and indexes using the low and high edges of
external switch signals.
For setting the communication speed of the RS-232C terminal.
9600 :Communicate at a rate of 9600 bps
19200:Communicate at a rate of 19200 bps
71
Parameter Possible settings Description
232C [TYPE1]
PROTOCOL TYPE TYPE2
TYPE3
TYPE4
TYPE5
TYPE6
TYPE7
TYPE8
232C [T1]
T2
T3
T4
T5
T6
T7
T8
MENU
MENU
Set this item according to the type of controller connected when performing remote
control using the RS-232C terminal.
TYPE1 :Standard operation mode
TYPE2 :For customized use
TYPE3~TYPE8 : Spare