No. 52026
A
V-14F3/AV-1435
A
V-1435EE/AV-1435TEE
A
V-14FMT3/AV-1438
A
V-14FMG3/AV-14FMG3
B
25
Item Measuring
instrument Test point Adjustment part Description
6. TINT [Method of adjustment without measuring instrument]
NTSC 3.58 TINT 1. Input a NTSC 3.58 full fie ld colo ur b ar si gnal (75% white) .
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVIC E MENU.
4. Select 6. TINT with the MENU / key.
5. Set the initial setting value of NTSC 3.58 with the MENU - / +
key.
6. If you c ann ot get the best tin t wi th th e in itial set tin g val ue, m ake
fine adjustment until you get the best tint.
Adju s t men t
of TINT
Signal
generator
Remote
control unit
NTSC 4.43 TINT When N TSC 3.5 8 is s et, N TSC 4. 43 wi ll be autom atica lly s et at t he
respec tive values .
6. TINT [Method of adjustment using measuring instrument]
NTSC 3.58 TINT 1. Input a NTSC 3.5 8 full field colour bar si gnal (75% w hite).
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVIC E MENU.
4. Select 6. TINT with the MENU / key.
5. Set the initial setting value of NTSC 3.58 with the MENU - / +
key.
6. Connect the osc ill osc ope be twee n TP-4 7G/ R and TP-E. (#).
7. Adjust NTSC 3.58 TINT to bring the value of (B) in the
illustration +9V(W- Cy). (Volta ge val ue be twee n (W) an d (Cy))
Adju s t men t
of TINT
Signal
generator
Oscillo-
scope
Remote
control unit
TP-47G/R
TP-E (#
##
#)
[CRT
SOCKET
PWB]
NTSC 4.43 TINT When N TSC 3.5 8 is s et, N TSC 4. 43 wi ll be autom atica lly s et at t he
respec tive values .
W
Y
C
y
G
M
g
R
B
(
B
)
0V
()
()